A comparison of 99mTc-exametazime and 123I-FP-CIT SPECT imaging in the differential diagnosis of Alzheimer's disease and dementia with Lewy bodies.
Аннотация
BACKGROUND
The aim of this study is to investigate the diagnostic value of perfusion 99mTc-exametazime single photon emission computed tomography (SPECT) in the diagnosis of dementia with Lewy bodies (DLB) and Alzheimer's disease (AD) in comparison with dopaminergic 123I-2beta-carbomethoxy-3beta-(4-iodophenyl)-n-(3-fluoropropyl) nortropane (FP-CIT) SPECT imaging.
METHODS
Subjects underwent 99mTc-exametazime scanning (39 controls, 36 AD, 30 DLB) and 123I-FP-CIT scanning (33 controls, 33 AD, 28 DLB). For each scan, five raters performed visual assessments blind to clinical diagnosis on selected transverse 99mTc-exametazime images in standard stereotactic space. Diagnostic accuracy of 99mTc-exametazime was compared to 123I-FP-CIT results for the clinically relevant subgroups AD and DLB using receiver operating characteristic (ROC) curve analysis.
RESULTS
Inter-rater agreement for categorizing uptake was "moderate" (mean kappa = 0.53) for 99mTc-exametazime and "excellent" (mean kappa = 0.88) for 123I-FP-CIT. For AD and DLB, consensus rating matched clinical diagnosis in 56% of cases using 99mTc-exametazime and 84% using 123I-FP-CIT. In distinguishing AD from DLB, ROC analysis revealed superior diagnostic accuracy with 123I-FP-CIT (ROC curve area 0.83, sensitivity 78.6%, specificity 87.9%) compared to occipital 99mTc-exametazime (ROC curve area 0.64, sensitivity 64.3%, specificity 63.6%) p = 0.03.
CONCLUSION
Diagnostic accuracy was superior with 123I-FP-CIT compared to 99mTc-exametazime in the differentiation of DLB from AD.