MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mao.0000000000002358

Медицинская библиотека · Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2019

Electrophysiologic Characteristics of Various Degrees of Selective Outer Hair Cell Loss in Rats.

Huang Wenqin, Chen Shulin, Dong Chang, Li Changwu, Sun Liang, Wang Xianren, Jiang Hongyan

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

HYPOTHESIS: The characteristics of auditory brainstem response (ABR), electrocochleogram (ECochG), and distortion product otoacoustic emissions (DPOAE) of different degrees of selective outer hair cells (OHCs) loss may be helpful for clinicians to evaluate the pathogeny, diagnosis, and rehabilitation of individuals' hearing loss.

BACKGROUND

How many OHCs are necessary to maintain cochlear amplifier function remains unknown. The electrophysiologic characteristics may indicate different degrees of OHCs loss.

METHODS

Electrophysiological characteristics were tested using 8-kHz pure-tone stimulus and OHCs counted specifically in the region of the cochlea corresponding to 8-kHz. Rat models of selective OHCs loss were established by injecting kanamycin (KM) at various dosages, and the region of 8-kHz was obtained by 8-kHz pure-tone exposure.

RESULTS

The ABR thresholds were affected slightly with OHCs loss < 30%, and were increased dramatically with OHCs loss ranging from 30 to 70%, but the thresholds did not increase further when OHCs loss exceeded 70%. As OHCs loss increased, the compound action potential (CAP) amplitude decreased. The CAP amplitude and OHCs loss were negatively correlated. Moreover, the summating potential (SP)/action potential (AP) increased as OHCs loss increased. DPOAE and cochlear microphonics (CM) exhibited reduced amplitudes when OHCs loss < 30%.

CONCLUSIONS

Electrophysiologic characteristics may indicate different degrees of OHCs loss. While OHCs loss > 70%, the cochlear amplification may lose completely, but it is difficult to detect OHCs loss < 30%, because the ABR or DPOAE may reveal "normal" at this level. Moreover, the decreased CAP amplitude or increased SP/AP may be indicators for OHCs loss.

Для цитирования: Huang Wenqin, Chen Shulin, Dong Chang, Li Changwu, Sun Liang, Wang Xianren, Jiang Hongyan. Electrophysiologic Characteristics of Various Degrees of Selective Outer Hair Cell Loss in Rats.. Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 2019. DOI: 10.1097/mao.0000000000002358.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.