MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.fas.2025.10.010

Медицинская библиотека · Foot and ankle surgery : official journal of the European Society of Foot and Ankle Surgeons · 2025

Validation of an intraoperative plantar pressure system in anesthetized patients.

Matsumoto Takumi, Hara Kazuaki, Grossman Jack, Shiuchi Kodai, Takeda Ryutaro, Chang Song Ho, An Qi, Tanaka Sakae, Sakuma Ichiro, Kobayashi Etsuko

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Achieving precise three-dimensional reconstruction during foot and ankle corrective surgeries is challenging. Intraoperative plantar pressure measurement (IPPM) can help assess foot morphology and detect abnormal pressure distributions. We developed an IPPM system using a navigation to align the floor reaction force with the femoral head's center. This study evaluates its accuracy in anesthetized patients.

PATIENTS AND

METHODS

Fifteen patients undergoing lower limb surgery were enrolled. Plantar pressure was measured intraoperatively in the supine position and compared with preoperative standing measurements. Similarity was evaluated using normalized cross-correlation (NCC) and peak pressure site agreement across 12 predefined foot regions.

RESULTS

The IPPM device replicated standing plantar pressure, with a mean NCC of 0.92 ± 0.1 and a peak pressure site agreement rate of 76.7 ± 37.2 %.

CONCLUSIONS

The newly developed intraoperative plantar pressure-measuring device accurately replicates standing plantar pressure in anesthetized patients, offering potential for improving intraoperative assessments and corrective procedures.

Для цитирования: Matsumoto Takumi, Hara Kazuaki, Grossman Jack, Shiuchi Kodai, Takeda Ryutaro, Chang Song Ho, An Qi, Tanaka Sakae, Sakuma Ichiro, Kobayashi Etsuko. Validation of an intraoperative plantar pressure system in anesthetized patients.. Foot and ankle surgery : official journal of the European Society of Foot and Ankle Surgeons. 2025. DOI: 10.1016/j.fas.2025.10.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.