Аннотация

Background

Treatment of pelvic injuries poses serious problems for surgeons due to the difficulties of the associated injuries. The objective of this research is to create a clinical workflow that integrates three-dimensional technologies in preoperative planning and performing surgery for the reduction and stabilization of associated acetabular fractures.

Methods

The research methodology consisted of integrating the stages of virtual preoperative planning, physical preoperative planning, and performing the surgical intervention in a newly developed clinical workflow. The proposed model was validated in practice in a pilot surgical intervention.

Results

On a complex pelvic injury case of a patient with an associated both-column acetabular fracture (AO/OTA-62C1g), we presented the results obtained in the six stages of the clinical workflow: acquisition of three-dimensional (3D) images, creation of the virtual model of the pelvis, creation of the physical model of the pelvis, preoperative physical simulation, orthopedic surgery, and imaging validation of the intervention. The life-size 3D model was fabricated based on computed tomography imagistics. To create the virtual model, the images were imported into Invesalius (version 3.1.1, CTI, Brazil), after which they were processed with MeshLab (version 2023.12, ISTI-CNR, Italy) and FreeCAD (version 0.21.2, LGPL, FSF, Boston, MA, USA). The physical model was printed in 21 h and 37 min using Ultimaker Cura software (version 5.7.2), on an Ultimaker 2+ printing machine through a Fused Deposition Modeling process. Using the physical model, osteosynthesis plate dimensions and fixation screw trajectories were tested to reduce the risk of neurovascular injury, after which they were adjusted and resterilized, which enhanced preoperative decision-making.

Conclusions

The life-size physical model improved anatomical appreciation and preoperative planning, enabling accurate surgical simulation. The tools created demonstrated remarkable accuracy and cost-effectiveness that support the advancement and efficiency of clinical practice.

Для цитирования: Solyom Arpad, Moldovan Flaviu, Moldovan Liviu, Strnad Gabriela, Fodor Pal. Clinical Workflow Algorithm for Preoperative Planning, Reduction and Stabilization of Complex Acetabular Fractures with the Support of Three-Dimensional Technologies.. Journal of clinical medicine. 2024. DOI: 10.3390/jcm13133891.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.