Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2024
Effect of different lumbar-iliac fixation and sacral slope for Tile C1.3 pelvic fractures: a biomechanical study.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Fan Shicai, Luo Hongjie, Chen Sheqiang, Xiang Haibo, Mai Qiguang, Zhu Zhenhua, Chen Yuhui, Hou Zhiyong, Chen Wei, Zhu Qingan, Zhang Yingze
Аннотация
BACKGROUND: Lumbar-iliac fixation (LIF) is a common treatment for Tile C1.3 pelvic fractures, but different techniques, including L4-L5/L5 unilateral LIF (L4-L5/L5 ULIF), bilateral LIF (BLIF), and L4-L5/L5 triangular osteosynthesis (L4-L5/L5 TOS), still lack biomechanical evaluation. The sacral slope (SS) is key to the vertical shear of the sacrum but has not been investigated for its biomechanical role in lumbar-iliac fixation. The aim of this study is to evaluate the biomechanical effects of different LIF and SS on Tile C1.3 pelvic fracture under two-legged standing load in human cadavers.
METHODS: Eight male fresh-frozen human lumbar-pelvic specimens were used in this study. Compressive force of 500 N was applied to the L4 vertebrae in the two-legged standing position of the pelvis. The Tile C1.3 pelvic fracture was prepared, and the posterior pelvic ring was fixed with L5 ULIF, L4-L5 ULIF, L5 TOS, L4-L5 TOS, and L4-L5 BLIF, respectively. Displacement and rotation of the anterior S1 foramen at 30° and 40° sacral slope (SS) were analyzed.
RESULTS: The displacement of L4-L5/L5 TOS in the left-right and vertical direction, total displacement, and rotation in lateral bending decreased significantly, which is more pronounced at 40° SS. The difference in stability between L4-L5 and L5 ULIF was not significant. BLIF significantly limited left-right displacement. The ULIF vertical displacement at 40° SS was significantly higher than that at 30° SS.
CONCLUSIONS: This study developed an in vitro two-legged standing pelvic model and demonstrated that TOS enhanced pelvic stability in the coronal plane and cephalad-caudal direction, and BLIF enhanced stability in the left-right direction. L4-L5 ULIF did not further improve the immediate stability, whereas TOS is required to increase the vertical stability at greater SS.
METHODS: Eight male fresh-frozen human lumbar-pelvic specimens were used in this study. Compressive force of 500 N was applied to the L4 vertebrae in the two-legged standing position of the pelvis. The Tile C1.3 pelvic fracture was prepared, and the posterior pelvic ring was fixed with L5 ULIF, L4-L5 ULIF, L5 TOS, L4-L5 TOS, and L4-L5 BLIF, respectively. Displacement and rotation of the anterior S1 foramen at 30° and 40° sacral slope (SS) were analyzed.
RESULTS: The displacement of L4-L5/L5 TOS in the left-right and vertical direction, total displacement, and rotation in lateral bending decreased significantly, which is more pronounced at 40° SS. The difference in stability between L4-L5 and L5 ULIF was not significant. BLIF significantly limited left-right displacement. The ULIF vertical displacement at 40° SS was significantly higher than that at 30° SS.
CONCLUSIONS: This study developed an in vitro two-legged standing pelvic model and demonstrated that TOS enhanced pelvic stability in the coronal plane and cephalad-caudal direction, and BLIF enhanced stability in the left-right direction. L4-L5 ULIF did not further improve the immediate stability, whereas TOS is required to increase the vertical stability at greater SS.