MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00004424-199711000-00003

Медицинская библиотека · Investigative radiology · 1997

Computed tomography-guided transtracheal needle aspiration of paratracheal lymphadenopathy in endoscopically normal patients.

Ewert R, Dörffel W, Rogalla P, Mutze S

СтатьяПеревод пока не подготовлен

Аннотация

RATIONALE AND

OBJECTIVES

The authors investigated the diagnostic value of computed tomography-guided bronchoscopic transtracheal needle biopsy of paratracheal lymphadenopathy without any endoscopical signs of stenosis or protrusion.

METHODS

Twenty consecutive patients with an age of 22 to 76 years underwent fiberoptic bronchoscopy with transtracheal needle biopsy under computed tomography guidance of paratracheal lymphadenopathies (diameter between 10 to 19 mm). Computed tomography fluoroscopy as a special low-dose computed tomography technique was used in the region of interest. The results of needle aspirates (cytologic examination) were verified by surgical interventions (n = 4), mediastinoscopy (n = 9), percutaneous needle biopsy (n = 1), or clinical/radiologic follow-up (n = 10).

RESULTS

All patients were without endoscopic signs of lymphadenopathy or tumor. Sufficient material of lymphatic tissue for cytologic assessment was obtained in 23 out of 24 patients (96%). In 5 of 10 patients with malignant diseases and 13 of 14 patients with benign enlarged lymph nodes, the lymph nodes were demonstrated exactly by transtracheal needle biopsy. There were no bleeding complications.

CONCLUSIONS

Computed tomography-guided bronchoscopic needle biopsy of paratracheal lymphadenopathy is a low-risk procedure. If malignant cells can be demonstrated with these technique, other more invasive procedures (surgery, mediastinoscopy) can be avoided. The numerous false-negative results (5 of 10) suggest, that the cytologic evidence of benign cells is without any diagnostic value in cases of paratracheal lymphadenopathy.

Для цитирования: Ewert R, Dörffel W, Rogalla P, Mutze S. Computed tomography-guided transtracheal needle aspiration of paratracheal lymphadenopathy in endoscopically normal patients.. Investigative radiology. 1997. DOI: 10.1097/00004424-199711000-00003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.