Zhonghua zhong liu za zhi [Chinese journal of oncology] · 2002
[Lymphoscintigraphy in sentinel lymph node biopsy of breast cancer].
Аннотация на английскомСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Zhang Jie, Shen Kunwei, Nirmal Lamichhane, Liu Guangyu, Wu Jiong, Zhang Yingjian, Du Huifeng, Pan Zhangchi, Shao Zhimin, Shen Zhenzhou
Аннотация
OBJECTIVE: To evaluate the feasibility of lymphoscintigraphy in sentinel lymph node biopsy of breast cancer.
METHOD: Lymphoscintigraphy was performed after peritumoral or subdermal injection of radioactive colloid. Then, sentinel lymph node (SLN) biopsy guided by gamma detector probe was performed. Factors correlated with identification-detection rate were assessed.
RESULTS: Lymphatic drainage was present in preoperative lymphoscintigraphy in 88(93%) out of 95 patients, with 39 (44.3%) positive for lymphatic drainage other than in the axilla. A total of 91 (95.8%) patients had their SLN identified in the intraoperative procedure. The quality of lymphoscintigraphic image was closely related to SLN identification-detection rate in the intraoperative procedure (P = 0.025).
CONCLUSION: Sentinel lymph node outside the axilla can be detected by lymphoscintigraphy. The combination of lymphoscintigraphy and gamma detector probe for sentinel lymph node biopsy of breast cancer not only is acceptable but promising.
METHOD: Lymphoscintigraphy was performed after peritumoral or subdermal injection of radioactive colloid. Then, sentinel lymph node (SLN) biopsy guided by gamma detector probe was performed. Factors correlated with identification-detection rate were assessed.
RESULTS: Lymphatic drainage was present in preoperative lymphoscintigraphy in 88(93%) out of 95 patients, with 39 (44.3%) positive for lymphatic drainage other than in the axilla. A total of 91 (95.8%) patients had their SLN identified in the intraoperative procedure. The quality of lymphoscintigraphic image was closely related to SLN identification-detection rate in the intraoperative procedure (P = 0.025).
CONCLUSION: Sentinel lymph node outside the axilla can be detected by lymphoscintigraphy. The combination of lymphoscintigraphy and gamma detector probe for sentinel lymph node biopsy of breast cancer not only is acceptable but promising.