MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/rti.0000000000000813

Медицинская библиотека · Journal of thoracic imaging · 2025

The Azygos Esophageal Recess Is Not to Be Missed in Screening Lung Cancer With LDCT.

Mascalchi Mario, Cavigli Edoardo, Picozzi Giulia, Cozzi Diletta, De Luca Giulia Raffaella, Diciotti Stefano

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Lesion overlooking and late diagnostic workup can compromise the efficacy of low-dose CT (LDCT) screening of lung cancer (LC), implying more advanced and less curable disease stages. We hypothesized that the azygos esophageal recess (AER) of the right lower lobe (RLL) might be an area prone to lesion overlooking in LC screening.

MATERIALS AND

METHODS

Two radiologists reviewed the LDCT examinations of all the screen-detected incident LCs observed in the active arm of 2 randomized clinical trials: ITALUNG and national lung screening trial. Those in the AER were compared with those in the remainder of the RLL for possible differences in diagnostic lag according to the Lung-RADS 1.1 recommendations, size, stage, and mortality.

RESULTS

Six (11.7%) of 51 screen-detected incident LCs of the RLL were located in the AER. The diagnostic lag time was significantly longer ( P =0.046) in the AER LC (mean 14±9 mo) than in the LC in the remaining RLL (mean 7.3±1 mo). Size and stage at diagnosis were not significantly different. All 6 subjects with LC in the AER and 16 (35.5%) of 45 subjects with LC in the remaining RLL ( P =0.004) died of LC after a median follow-up of 12 years.

CONCLUSION

Our retrospective study indicates that AER might represent a lung region of the RLL prone to have early LC overlooked due to detection or interpretation errors with possible detrimental consequences for the subject undergoing LC screening.

Для цитирования: Mascalchi Mario, Cavigli Edoardo, Picozzi Giulia, Cozzi Diletta, De Luca Giulia Raffaella, Diciotti Stefano. The Azygos Esophageal Recess Is Not to Be Missed in Screening Lung Cancer With LDCT.. Journal of thoracic imaging. 2025. DOI: 10.1097/rti.0000000000000813.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.