BACKGROUND

Transradial access for neurointerventions offers advantages of fewer access-site complications, reduced procedure time, and greater patient comfort over transfemoral access. Data about transradial access for flow diversion are limited. We share our early experience with transradial access for flow diversion in a relatively large case series.

METHODS

Consecutive patients who underwent Pipeline embolization device (Medtronic) deployment via transradial access were included in the study, irrespective of location and laterality of the intracranial aneurysm. The cases were performed between July 2016 and October 2019. Demographics, aneurysm characteristics, and procedure-related details (including catheter systems used) were recorded and statistically evaluated.

RESULTS

Thirty-five transradial flow diversion procedures were attempted in 32 patients, of which 33 procedures were successful. In two cases involving left common carotid artery and internal carotid artery access, guide catheter herniation into the aortic arch led to abandonment of transradial access in favor of transfemoral access. The most common aneurysm locations in the transradial access procedures were the posterior communicating artery (n = 7), ophthalmic artery (n = 7), and superior hypophyseal artery (n = 7). Most transradial access procedures (66.7%) were performed using a biaxial catheter system. 6-French Benchmark (Penumbra) and Phenom 27 (Medtronic) were the most commonly utilized guide- and microcatheters, respectively. One patient had intraprocedural subarachnoid hemorrhage. No access-site complications occurred.

CONCLUSION

This study demonstrates safety and feasibility of transradial access for Pipeline embolization device deployment and shows the versatility of this approach for different catheter systems. Tortuosity and acute angulation of the left common carotid artery and internal carotid artery were associated with approach failure.

Для цитирования: Waqas Muhammad, Vakharia Kunal, Dossani Rimal H, Rajah Gary B, Tso Michael K, Gong Andrew D, Rho Kyungduk, Rai Hamid H, Snyder Kenneth V, Levy Elad I, Siddiqui Adnan H, Davies Jason M. Transradial access for flow diversion of intracranial aneurysms: Case series.. Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences. 2020. DOI: 10.1177/1591019920938961.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.