MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/codi.70362

Медицинская библиотека · Colorectal disease : the official journal of the Association of Coloproctology of Great Britain and Ireland · 2026

Second-generation capsule endoscopy for the detection of colorectal polyps: An updated systematic review and comparative meta-analysis of prospective studies.

Câmara Cauã Ferreira, Passos Pedro Robson Costa, Cezar Ettore Carvalho Lopes, Filho José Nilo de Lima, Oliveira Rafael Mariano Araújo, de Paiva Carlos Yuri Monteiro, Quintela Adriely Oliveira, de Andrade Alana Ferreira, Veras Lara Burlamaqui

СтатьяСистематический обзорМетаанализСравнительное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

Colorectal cancer (CRC) is the third most common cancer worldwide and the second leading cause of cancer-related death. Colonoscopy (CO) is the gold standard for screening, but its invasive nature and low adherence limit its use. Second-generation capsule endoscopy (CCE-2) emerges as a non-invasive alternative. This study aimed to evaluate the diagnostic accuracy of CCE-2 in detecting colorectal polyps, using CO as the reference standard.

METHODS

A systematic review and meta-analysis of prospective studies in adults undergoing CCE-2 followed by CO was performed. Searches were conducted in PubMed, EMBASE and Cochrane up to May 2025. Diagnostic accuracy metrics were pooled using a Bayesian bivariate model with construction of HSROC curves. To assess clinical impact, a fictitious cohort of 1000 patients was simulated based on polyp prevalence and submitted to decision curve analysis (DCA).

RESULTS

Twelve studies including 4316 patients were analysed. CCE-2 demonstrated sensitivity/specificity of 0.89/0.94 for polyps ≥6 mm and 0.91/0.98 for ≥10 mm. In FIT-positive patients, performance was superior. In the simulated cohort, CCE-2 showed greater net benefit from a 20% pre-test probability threshold of a patient to have a polyp of any size, surpassing the universal CO strategy, avoiding unnecessary colonoscopies to make this diagnostic.

CONCLUSION

CCE-2 is a non-invasive, safe and accurate alternative for CRC screening, with potential to increase adherence, particularly in patients with contraindications or refusal of CO. However, the lack of therapeutic capability and absence of evidence regarding mortality reduction limit its role as a first-line tool. Randomized clinical trials are needed to consolidate its role in personalized screening.

Для цитирования: Câmara Cauã Ferreira, Passos Pedro Robson Costa, Cezar Ettore Carvalho Lopes, Filho José Nilo de Lima, Oliveira Rafael Mariano Araújo, de Paiva Carlos Yuri Monteiro, Quintela Adriely Oliveira, de Andrade Alana Ferreira, Veras Lara Burlamaqui. Second-generation capsule endoscopy for the detection of colorectal polyps: An updated systematic review and comparative meta-analysis of prospective studies.. Colorectal disease : the official journal of the Association of Coloproctology of Great Britain and Ireland. 2026. DOI: 10.1111/codi.70362.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.