MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jmir.2024.03.004

Медицинская библиотека · Journal of medical imaging and radiation sciences · 2024

Impact of a contouring atlas on radiographer inter-observer variation in male pelvis radiotherapy.

Clough Abigael, Chuter Robert, Hales Rosie B, Parker Jacqui, McMahon John, Whiteside Lee, McHugh Louise, Davies Lucy, Sanders Josephine, Benson Rebecca, Nelder Claire, McDaid Lisa, Choudhury Ananya, Eccles Cynthia L

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE/

OBJECTIVE

To determine the impact of a MR-based contouring atlas for male pelvis radiotherapy delineation on inter-observer variation to support radiographer led real-time magnetic resonance image guided adaptive radiotherapy (MRgART).

MATERIAL/

METHODS

Eight RTTs contoured 25 MR images in the Monaco treatment planning system (Monaco 5.40.01), from 5 patients. The prostate, seminal vesicles, bladder, and rectum were delineated before and after the introduction of an atlas developed through multi-disciplinary consensus. Inter-observer contour variations (volume), time to contour and observer contouring confidence were determined at both time-points using a 5-point Likert scale. Descriptive statistics were used to analyse both continuous and categorical variables. Dice similarity coefficient (DSC), Dice-Jaccard coefficient (DJC) and Hausdorff distance were used to calculate similarity between observers.

RESULTS

Although variation in volume definition decreased for all structures among all observers post intervention, the change was not statistically significant. DSC and DJC measurements remained consistent following the introduction of the atlas for all observers. The highest similarity was found in the bladder and prostate whilst the lowest was the seminal vesicles. The mean contouring time for all observers was reduced by 50% following the introduction of the atlas (53 to 27 minutes, p=0.01). For all structures across all observers, the mean contouring confidence increased significantly from 2.3 to 3.5 out of 5 (p=0.02).

CONCLUSION

Although no significant improvements were observed in contour variation amongst observers, the introduction of the consensus-based contouring atlas improved contouring confidence and speed; key factors for a real-time RTT-led MRgART.

Для цитирования: Clough Abigael, Chuter Robert, Hales Rosie B, Parker Jacqui, McMahon John, Whiteside Lee, McHugh Louise, Davies Lucy, Sanders Josephine, Benson Rebecca, Nelder Claire, McDaid Lisa, Choudhury Ananya, Eccles Cynthia L. Impact of a contouring atlas on radiographer inter-observer variation in male pelvis radiotherapy.. Journal of medical imaging and radiation sciences. 2024. DOI: 10.1016/j.jmir.2024.03.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.