Intra-fractional geometric and dose/volume metric variations of magnetic resonance imaging-guided stereotactic radiotherapy of prostate bed after radical prostatectomy.

Gao Yu, Yoon Stephanie, Ma Ting Martin, Yang Yingli, Sheng Ke, Low Daniel A, Ballas Leslie, Steinberg Michael L, Kishan Amar U, Cao Minsong

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: Magnetic Resonance Imaging (MRI)-guided Stereotactic body radiotherapy (SBRT) treatment to prostate bed after radical prostatectomy has garnered growing interests. The aim of this study is to evaluate intra-fractional anatomic and dose/volume metric variations for patients receiving this treatment.

MATERIALS AND

METHODS

Nineteen patients who received 30-34 Gy in 5 fractions on a 0.35T MR-Linac were included. Pre- and post-treatment MRIs were acquired for each fraction (total of 75 fractions). The Clinical Target Volume (CTV), bladder, rectum, and rectal wall were contoured on all images. Volumetric changes, Hausdorff distance, Mean Distance to Agreement (MDA), and Dice similarity coefficient (DSC) for each structure were calculated. Median value and Interquartile range (IQR) were recorded. Changes in target coverage and Organ at Risk (OAR) constraints were compared and evaluated using Wilcoxon rank sum tests at a significant level of 0.05.

RESULTS

Bladder had the largest volumetric changes, with a median volume increase of 48.9 % (IQR 28.9-76.8 %) and a median MDA of 5.1 mm (IQR 3.4-7.1 mm). Intra-fractional CTV volume remained stable with a median volume change of 1.2 % (0.0-4.8 %). DSC was 0.97 (IQR 0.94-0.99). For the dose/volume metrics, there were no statistically significant changes observed except for an increase in bladder hotspot and a decrease of bladder V32.5 Gy and mean dose. The CTV V95% changed from 99.9 % (IQR 98.8-100 %) to 99.6 % (IQR 93.9-100 %).

CONCLUSION

Despite intra-fractional variations of OARs, CTV coverage remained stable during MRI-guided SBRT treatments for the prostate bed.

Для цитирования: Gao Yu, Yoon Stephanie, Ma Ting Martin, Yang Yingli, Sheng Ke, Low Daniel A, Ballas Leslie, Steinberg Michael L, Kishan Amar U, Cao Minsong. Intra-fractional geometric and dose/volume metric variations of magnetic resonance imaging-guided stereotactic radiotherapy of prostate bed after radical prostatectomy.. Physics and imaging in radiation oncology. 2024. DOI: 10.1016/j.phro.2024.100573.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.