m+Medelevator.RU
← Поиск публикаций
Journal of the American Veterinary Medical Association · 2024

Noncontact infrared thermometer measurements offer a reasonable alternative to rectal temperature measurement in afebrile horses.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zobrist Chelsea N, Bishop Rebecca C, McCoy Annette M

Аннотация

OBJECTIVE: To assess the repeatability of infrared thermometer temperature readings and evaluate the correlation between digital rectal temperature and infrared thermometer temperatures taken at different locations in healthy afebrile horses.

ANIMALS: 101 afebrile horses ≥ 1 year old.

METHODS: Digital rectal temperatures and infrared temperatures from the eye, gingiva, neck, axilla, and perineum were obtained in a climate-controlled environment and at 2 outdoor ambient temperatures (study period, November 1, 2021, to April 30, 2023).

RESULTS: Infrared temperature measurements were well tolerated by horses, including those resistant to rectal temperature. There was significant correlation between rectal temperature and infrared temperature taken at the perineum (R = 0.57; P < .001) and eye (R = 0.37; P < .001). Infrared temperature measurements were highly repeatable, allowing for calculation of reference ranges for the perineum (36.0 to 37.8 °C) and eye (35.7 to 37.1 °C) in climate-controlled conditions. There was increased variance in outside temperatures compared to climate-controlled conditions for the eye (P = .002), gingiva (P = .047), and perineum (P = .005).

CLINICAL RELEVANCE: While infrared thermometer temperatures were not numerically the same as rectal temperature using a digital thermometer, measurements at the perineum and eye were correlated with rectal temperature readings. Further, the repeatability of infrared readings allows for computation of reference ranges that make the infrared thermometer a viable alternative for the practicing veterinarian when obtaining a temperature in uncooperative horses. The infrared thermometer was reliable outdoors for the eye, but not the perineum. Additional validation of infrared temperature reference ranges in febrile horses and warmer ambient temperatures is warranted.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты