Arsenic trioxide-eluting electrospun nanofiber-covered self-expandable metallic stent reduces granulation tissue hyperplasia in rabbit trachea.

Li Yahua, Li Mengde, Wang Xiaofeng, Wang Yuhui, Li Chang, Zhao Yanan, Li Zhaonan, Chen Jianjian, Li Jing, Ren Kewei, Duan Xuhua, Ren Jianzhuang, Han Xinwei, Li Qian

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Stent-related granulation tissue hyperplasia is a major complication that limits the application of stents in airways. In this study, an arsenic trioxide-eluting electrospun nanofiber-covered self-expandable metallic stent (ATO-NFCS) was developed. Poly-L-lactide-caprolactone (PLCL) was selected as the drug-carrying polymer. Stents with two different ATO contents (0.4% ATO/PLCL and 1.2% ATO/PLCL) were fabricated. The in vitro release in simulated airway fluid suggested that the total ATO release time was 1 d. The growth of human embryonic pulmonary fibroblasts (CCC-HPF-1), normal human bronchial epithelial cells and airway smooth muscle cells was inhibited by ATO. When embedded in paravertebral muscle, the nanofiber membrane showed good short-term and long-term biological effects. In an animal study, placement of the ATO-NFCS in the trachea through a delivery system under fluoroscopy was feasible. The changes in liver and kidney function 1 and 7 d after ATO-NFCS placement were within the normal range. On pathological examination, the heart, liver, spleen, lungs and kidneys were normal. The effectiveness of the ATO-NFCS in reducing granulation tissue hyperplasia and collagen deposition was demonstrated in the rabbit airway (n = 18) at 4 weeks. The present study preliminarily investigated the efficacy of the ATO-NFCS in reducing granulation tissue formation in the trachea of rabbits. The results suggest that the ATO-NFCS is safe in vivo, easy to place, and effective for the suppression of granulation tissue formation.

Для цитирования: Li Yahua, Li Mengde, Wang Xiaofeng, Wang Yuhui, Li Chang, Zhao Yanan, Li Zhaonan, Chen Jianjian, Li Jing, Ren Kewei, Duan Xuhua, Ren Jianzhuang, Han Xinwei, Li Qian. Arsenic trioxide-eluting electrospun nanofiber-covered self-expandable metallic stent reduces granulation tissue hyperplasia in rabbit trachea.. Biomedical materials (Bristol, England). 2020. DOI: 10.1088/1748-605x/abb25a.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.