MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.resinv.2020.09.009

Медицинская библиотека · Respiratory investigation · 2020

A comparative study of the Parker Flex-Tip tube versus standard portex tube for oral fiberoptic intubation in bronchoscopy performed by pulmonologists with limited experience.

Yamauchi Hiroyoshi, Nakayama Masayuki, Yamamoto Shinichi, Sata Masafumi, Mato Naoko, Bando Masashi, Hagiwara Koichi

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Fiberoptic tracheal intubation (FTI) in bronchoscopy is widely performed with a conventional Portex tracheal tube (PTT). Occasionally, it is difficult for pulmonologists with limited experience to insert a tube beyond the vocal cords and advance it into the trachea. A new endotracheal tube, the Parker Flex-Tip tube (PFT), was recently designed. We compared the usefulness and safety of PFT versus PTT for FTI in bronchoscopy performed by pulmonologists with limited experience.

METHODS

Forty consecutive patients were enrolled and randomly assigned to either the PFT group (n = 20) or PTT group (n = 20). The time required for the tip of the endotracheal tube to pass from the mouth to the carina, the number of vomiting reflexes, the number of attempts to pass the tube through the vocal cords during intubation, complications, and technical difficulty of intubation were evaluated.

RESULTS

Both the PFT and PTT groups exhibited high intubation success rates (100% vs. 90%, respectively). The PFT group was intubated faster than the PTT group (11.5 [5-45] s vs. 22.5 [8-270] s, respectively, p < 0.01). The PFT group showed fewer vomiting reflexes and tube impingements than the PTT group (p < 0.05). Operators felt it was easier to intubate with PFT versus PTT (p < 0.01). Complications were not significantly different between the two groups.

CONCLUSION

For pulmonologists with limited experience who perform FTI in bronchoscopy, intubation using PFT versus PTT is faster and easier, without an increase in complications.

Для цитирования: Yamauchi Hiroyoshi, Nakayama Masayuki, Yamamoto Shinichi, Sata Masafumi, Mato Naoko, Bando Masashi, Hagiwara Koichi. A comparative study of the Parker Flex-Tip tube versus standard portex tube for oral fiberoptic intubation in bronchoscopy performed by pulmonologists with limited experience.. Respiratory investigation. 2020. DOI: 10.1016/j.resinv.2020.09.009.