Successful tracheal necrosis management using a pedicle pectoralis flap: A case report.

Eftekhar Negar, Borjian Anahita, Rafieian Shahab, Borjian Mohammad Amin, Sahebi Mehdi Abbasi

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

Thyroidectomy is considered an overall low-risk procedure. However, severe life-threatening complications, including tracheal necrosis may occur postoperatively. A 45-year-old male patient was referred to our clinic for papillary thyroid carcinoma surgery. The patient had mediastinitis signs and symptoms seven days after total thyroidectomy. Subsequent imaging demonstrated air leak and with mediastinitis as the primary diagnosis, and the patient underwent reoperation. During the operation, four necrotic tracheal rings were found to be the source of air leak. Due to tissue inflammation and infection, neither primary repair with tracheal resection and anastomosis, nor strap muscle plugging procedure were feasible. Therefore, a pedicle flap derived from the right pectoralis major muscle was transferred to the necrotic trachea. The patient"s clinical condition improved after the operation and subsequent bronchoscopies confirmed healing of trachea. During six-month follow-up, no complications were observed. In conclusion, the technique discussed in the current report shows promising outcomes for reconstructing large tracheal defects in inflammatory conditions where primary repair techniques are not suitable.

Для цитирования: Eftekhar Negar, Borjian Anahita, Rafieian Shahab, Borjian Mohammad Amin, Sahebi Mehdi Abbasi. Successful tracheal necrosis management using a pedicle pectoralis flap: A case report.. Turk gogus kalp damar cerrahisi dergisi. 2020. DOI: 10.5606/tgkdc.dergisi.2020.18144.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.