MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejrad.2025.112192

Медицинская библиотека · European journal of radiology · 2025

Diagnostic accuracy of computed tomography in localizing gastrointestinal perforations: Focusing on gastric and duodenal defects.

Pavlovic Aleksandar, Herrington Tyler, Mijovic Ksenija, Gore Richard M, Vasin Dragan, Alessandrino Francesco, Ivanovic Aleksandar M

СтатьяПеревод в очереди

Аннотация

PURPOSE: To provide a detailed assessment of the accuracy and reproducibility of Computed Tomography (CT) in localizing gastrointestinal perforations, with a focus on distinguishing gastric and duodenal defects.

METHODS

This single-center retrospective study evaluated subjects with surgically confirmed gastrointestinal perforation who underwent preoperative contrast-enhanced abdominopelvic CT. Two subspecialized radiologists reviewed each CT independently to identify the perforation site, to differentiate gastroduodenal from perforations in other locations, and to differentiate between gastric and duodenal perforation, using defined CT signs such as gas inclusions, pneumoperitoneum, and thickened gastrointestinal walls. For gastroduodenal perforations, accuracy of Minimum Intensity Projection (MinIP) reconstructions was also assessed. Inter-reader agreement was calculated using Cohen's kappa statistics.

RESULTS

156 patients (M/F: 89/67; median age: 62 years) met inclusion criteria. CT accuracy in distinguishing all perforation sites was 73.1 % for Reviewer 1 and 67.9 % for Reviewer 2 (k = 0.72). When differentiating gastroduodenal from other perforations, accuracy increased to 94.9 % and 88.5 % (k = 0.86). Among gastroduodenal perforations (n = 56; 35.9 %), Reviewer 1 correctly differentiated gastric from duodenal perforation in 79.6 % of cases, and Reviewer 2 in 64.8 %. MinIP imaging increased accuracy to 87 % and 77.8 %, though not significantly (p = 0.47 and p = 0.21).

CONCLUSION

CT demonstrates high accuracy and reproducibility in localizing gastrointestinal perforations, particularly in differentiating gastric from duodenal defects- a critical distinction for surgical decision making. MinIP reconstructions may be useful as a novel diagnostic adjunct in this context. CT signs such as fluid, fat stranding, and wall thickening were seen in most perforations, though none correlated significantly with correct perforation localization.

Для цитирования: Pavlovic Aleksandar, Herrington Tyler, Mijovic Ksenija, Gore Richard M, Vasin Dragan, Alessandrino Francesco, Ivanovic Aleksandar M. Diagnostic accuracy of computed tomography in localizing gastrointestinal perforations: Focusing on gastric and duodenal defects.. European journal of radiology. 2025. DOI: 10.1016/j.ejrad.2025.112192.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.