Lin chuang er bi yan hou tou jing wai ke za zhi = Journal of clinical otorhinolaryngology head and neck surgery · 2012
[Study of voice changes pre- and post-tonsillectomy].
Аннотация на английскомСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Li Juan, Yan Yan, Wang Li, Duan Jingming, Zhang Ke
Аннотация
OBJECTIVE: To evaluate changes in acoustic features of voice after tonsillectomy.
METHOD: Thirty-three patients presenting for tonsillectomy were recruited. Voice recordings obtained from patients before and 1 month after surgery, were analyzed using the Kay Elemetrics, multi-dimensional voice processing software. The following parameters were estimated: the first formant (F1, B1), average of fundamental frequency (F0), Jitter percent (Jitter), Shimmer, noise-to-harmonics ratio (NHR).
RESULT: There were significant difference in the first formant frequency and bandwidth before and 1 month after surgery. The larger the tonsil was, the more changes were seen in the formant frequency. No significant differences were found for F0, Jitter, Shimmer, NHR decreased after the surgery.
CONCLUSION: The modifications in the anatomical structure and volume of the vocal tract, induced by the tonsillectomy can change the formant frequency and bandwidth. The larger the tonsil was, the more changes were detected in the formant frequency.
METHOD: Thirty-three patients presenting for tonsillectomy were recruited. Voice recordings obtained from patients before and 1 month after surgery, were analyzed using the Kay Elemetrics, multi-dimensional voice processing software. The following parameters were estimated: the first formant (F1, B1), average of fundamental frequency (F0), Jitter percent (Jitter), Shimmer, noise-to-harmonics ratio (NHR).
RESULT: There were significant difference in the first formant frequency and bandwidth before and 1 month after surgery. The larger the tonsil was, the more changes were seen in the formant frequency. No significant differences were found for F0, Jitter, Shimmer, NHR decreased after the surgery.
CONCLUSION: The modifications in the anatomical structure and volume of the vocal tract, induced by the tonsillectomy can change the formant frequency and bandwidth. The larger the tonsil was, the more changes were detected in the formant frequency.