MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.radonc.2018.09.015

Медицинская библиотека · Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2018

Intrafraction motion quantification and planning target volume margin determination of head-and-neck tumors using cine magnetic resonance imaging.

Bruijnen Tom, Stemkens Bjorn, Terhaard Chris H J, Lagendijk Jan J W, Raaijmakers Cornelis P J, Tijssen Rob H N

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To quantify intrafractional motion to determine population-based radiotherapy treatment margins for head-and-neck tumors.

METHODS

Cine MR imaging was performed in 100 patients with head-and-neck cancer on a 3T scanner in a radiotherapy treatment setup. MR images were analyzed using deformable image registration (optical flow algorithm) and changes in tumor contour position were used to calculate the tumor motion. The tumor motion was used together with patient setup errors (450 patients) to calculate population-based PTV margins.

RESULTS

Tumor motion was quantified in 84 patients (12/43/29 nasopharynx/oropharynx/larynx, 16 excluded). The mean maximum (95th percentile) tumor motion (swallowing excluded) was: 2.3 mm in superior, 2.4 mm in inferior, 1.8 mm in anterior and 1.7 mm in posterior direction. PTV margins were: 2.8 mm isotropic for nasopharyngeal tumors, 3.2 mm isotropic for oropharyngeal tumors and 4.3 mm in inferior-superior and 3.2 mm in anterior-posterior for laryngeal tumors, for our institution.

CONCLUSIONS

Intrafractional head-and-neck tumor motion was quantified and population-based PTV margins were calculated. Although the average tumor motion was small (95th percentile motion <3.0 mm), tumor motion varied considerably between patients (0.1-12.0 mm). The intrafraction motion expanded the CTV-to-PTV with 1.7 mm for laryngeal tumors, 0.6 mm for oropharyngeal tumors and 0.2 mm for nasopharyngeal tumors.

Для цитирования: Bruijnen Tom, Stemkens Bjorn, Terhaard Chris H J, Lagendijk Jan J W, Raaijmakers Cornelis P J, Tijssen Rob H N. Intrafraction motion quantification and planning target volume margin determination of head-and-neck tumors using cine magnetic resonance imaging.. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. 2018. DOI: 10.1016/j.radonc.2018.09.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.