m+Medelevator.RU
← Поиск публикаций
Clinical hemorheology and microcirculation · 2014

Monitoring parotid gland tumors with a new perfusion software for contrast-enhanced ultrasound.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Klotz Laura V, Ingrisch Michael, Eichhorn Martin E, Niemoeller Olivier, Siedek Vanessa, Gürkov Robert, Clevert Dirk-Andre

Аннотация

PURPOSE: Contrast enhanced ultrasound (CE-US) is a promising imaging modality for non-invasive analysis of functional vascularisation. Lesions of the parotid gland are associated with a vascularisation that differs from normal gland tissue. The aim of this clinical study was to further analyse the perfusion in parotid gland lesions with CE-US. The new quantification software VueBox (Bracco, Italy) was used to assess the perfusion, based on DICOM datasets of CE-US examination.

MATERIALS AND METHODS: CE-US measurements were performed by intravenous application of a contrast agent (SonoVue, Bracco, Italy) before surgical tumor resection. From the analysis of a time sequence of 2D DICOM contrast images, area under time intensity curve (AUC), peak enhancement (PE), wash-in-rate (WiR) and wash-in-perfusion-index (WiPI) were calculated using VueBox. These were correlated with the histological analyses of the tumor tissue.

RESULTS: Significant difference of area below intensity time curve (AUC), peak enhancement (PE), wash-in-rate (WiR) and wash-in perfusion index (WiPI) were observed in the malign lesions compared to benign tumors (p < 0,05) and in pleomorphic adenoma compared to cystadenolymphoma (p < 0,05).

CONCLUSION: CE-US seems to be a quantitative and independent method for discriminating between malign and benign parotid gland tumors.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты