MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0178807

Медицинская библиотека · PloS one · 2017

Chest-MRI under pulsatile flow ventilation: A new promising technique.

Beigelman-Aubry Catherine, Peguret Nicolas, Stuber Matthias, Delacoste Jean, Belmondo Bastien, Lovis Alban, Simons Julien, Long Olivier, Grant Kathleen, Berchier Gregoire, Rohner Chantal, Bonanno Gabriele, Coppo Simone, Schwitter Juerg, Ozsahin Mahmut, Qanadli Salah, Meuli Reto, Bourhis Jean

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Magnetic resonance imaging (MRI) of the chest has long suffered from its sensitivity to respiratory and cardiac motion with an intrinsically low signal to noise ratio and a limited spatial resolution. The purpose of this study was to perform chest MRI under an adapted non invasive pulsatile flow ventilation system (high frequency percussive ventilation, HFPV®) allowing breath hold durations 10 to 15 times longer than other existing systems.

METHODS

One volunteer and one patient known for a thymic lesion underwent a chest MRI under ventilation percussion technique (VP-MR). Routinely used sequences were performed with and without the device during three sets of apnoea on inspiration.

RESULTS

VP-MR was well tolerated in both cases. The mean duration of the thoracic stabilization was 10.5 min (range 8.5-12) and 5.8 min (range 5-6.2) for Volunteer 1 and Patient 1, respectively. An overall increased image quality was seen under VP-MR with a better delineation of the mediastinal lesion for Patient 1. Nodules discovered in Volunteer 1 were confirmed with low dose CT.

CONCLUSION

VP-MR was feasible and increased spatial resolution of chest MRI by allowing acquisition at full inspiration during thoracic stabilization approaching prolonged apnoea. This new technique could be of benefit to numerous thoracic disorders.

Для цитирования: Beigelman-Aubry Catherine, Peguret Nicolas, Stuber Matthias, Delacoste Jean, Belmondo Bastien, Lovis Alban, Simons Julien, Long Olivier, Grant Kathleen, Berchier Gregoire, Rohner Chantal, Bonanno Gabriele, Coppo Simone, Schwitter Juerg, Ozsahin Mahmut, Qanadli Salah, Meuli Reto, Bourhis Jean. Chest-MRI under pulsatile flow ventilation: A new promising technique.. PloS one. 2017. DOI: 10.1371/journal.pone.0178807.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.