Ginès Angels, Fusaroli Pietro, Sendino Oriol, Seicean Andrada, Gimeno-Garcia Antonio Z, Gratacós-Ginès Jordi, Araujo Isis K, Rodríguez-Carunchio Leonardo, Alós Silvia, Lisotti Andrea, Cominardi Anna, Montenegro Andrea, Fernández-Esparrach Glòria

Аннотация

Background and study aims  The poor flexibility of large-bore EUS needles often leads to technical failure when sampling from the duodenum. The aim of this study was to evaluate the technical and diagnostic performances of a new Menghini tip 19G nitinol EUS needle for sampling pancreatic solid lesions in the head and uncinate process. Patients and methods  This was a European prospective multicenter single-arm study. A maximum of four passes were allowed. In case of failure, different needles were permitted. Results  We included 75 patients (51 % males) with lesions in the head (n = 68; 91 %) and uncinate process (n = 7; 9 %) (mean size: 33 ± 12 mm; number of passes: 1.8 ± 0.9). Technical success was seen in 71 of 75 (94.7 %). Diagnostic rates were 89.3 % (67/75) and 94.4 % (67/71) in the intention-to-treat (ITT) and per-protocol (PP) analysis, respectively. In the eight cases with failure, diagnosis was obtained with another needle (n = 4), from another lesion (n = 3) or with follow-up (n = 1). A histological sample was obtained in 64 patients (ITT 85.3 % and PP 90 %) and immunohistochemistry was successfully performed in 13 of 15 lesions in which it was required. No differences between rapid on-site evaluation (ROSE) and non-ROSE groups were observed regarding diagnostic success (87.5 % vs 91 %, P  = 0.582) and diagnosis at the first pass (70 % vs 81 %, P  = 0.289). Number of passes was lower in the ROSE group (1.4 + 0.9 vs 2.2 + 0.7, P  < 0.001). One adverse event was recorded (1.3 %) consisting in a duodenal perforation after a single session EUS-ERCP. Conclusions  The new nitinol Menghini tip 19G EUS needle showed high technical diagnostic success in safely sampling solid lesions in the head and uncinate process of the pancreas.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты