A multicenter randomized controlled trial of a 3-L/kg/min versus 2-L/kg/min high-flow nasal cannula flow rate in young infants with severe viral bronchiolitis (TRAMONTANE 2).

Milési Christophe, Pierre Anne-Florence, Deho Anna, Pouyau Robin, Liet Jean-Michel, Guillot Camille, Guilbert Anne-Sophie, Rambaud Jérôme, Millet Astrid, Afanetti Mickael, Guichoux Julie, Genuini Mathieu, Mansir Thierry, Bergounioux Jean, Michel Fabrice, Marcoux Marie-Odile, Baleine Julien, Durand Sabine, Durand Philippe, Dauger Stéphane, Javouhey Etienne, Leteurtre Stéphane, Brissaud Olivier, Renolleau Sylvain, Portefaix Aurélie, Douillard Aymeric, Cambonie Gilles, GFRUP Respiratory Study Group

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПеревод в очереди

Аннотация

PURPOSE: High-flow nasal cannula (HFNC) therapy is increasingly proposed as first-line respiratory support for infants with acute viral bronchiolitis (AVB). Most teams use 2 L/kg/min, but no study compared different flow rates in this setting. We hypothesized that 3 L/kg/min would be more efficient for the initial management of these patients.

METHODS

A randomized controlled trial was performed in 16 pediatric intensive care units (PICUs) to compare these two flow rates in infants up to 6 months old with moderate to severe AVB and treated with HFNC. The primary endpoint was the percentage of failure within 48 h of randomization, using prespecified criteria of worsening respiratory distress and discomfort.

RESULTS

From November 2016 to March 2017, 142 infants were allocated to the 2-L/kg/min (2L) flow rate and 144 to the 3-L/kg/min (3L) flow rate. Failure rate was comparable between groups: 38.7% (2L) vs. 38.9% (3L; p = 0.98). Worsening respiratory distress was the most common cause of failure in both groups: 49% (2L) vs. 39% (3L; p = 0.45). In the 3L group, discomfort was more frequent (43% vs. 16%, p = 0.002) and PICU stays were longer (6.4 vs. 5.3 days, p = 0.048). The intubation rates [2.8% (2L) vs. 6.9% (3L), p = 0.17] and durations of invasive [0.2 (2L) vs. 0.5 (3L) days, p = 0.10] and noninvasive [1.4 (2L) vs. 1.6 (3L) days, p = 0.97] ventilation were comparable. No patient had air leak syndrome or died.

CONCLUSION

In young infants with AVB supported with HFNC, 3 L/kg/min did not reduce the risk of failure compared with 2 L/kg/min. This clinical trial was recorded on the National Library of Medicine registry (NCT02824744).

Для цитирования: Milési Christophe, Pierre Anne-Florence, Deho Anna, Pouyau Robin, Liet Jean-Michel, Guillot Camille, Guilbert Anne-Sophie, Rambaud Jérôme, Millet Astrid, Afanetti Mickael, Guichoux Julie, Genuini Mathieu, Mansir Thierry, Bergounioux Jean, Michel Fabrice, Marcoux Marie-Odile, Baleine Julien, Durand Sabine, Durand Philippe, Dauger Stéphane, Javouhey Etienne, Leteurtre Stéphane, Brissaud Olivier, Renolleau Sylvain, Portefaix Aurélie, Douillard Aymeric, Cambonie Gilles, GFRUP Respiratory Study Group. A multicenter randomized controlled trial of a 3-L/kg/min versus 2-L/kg/min high-flow nasal cannula flow rate in young infants with severe viral bronchiolitis (TRAMONTANE 2).. Intensive care medicine. 2018. DOI: 10.1007/s00134-018-5343-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.