MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jmig.2018.11.006

Медицинская библиотека · Journal of minimally invasive gynecology · 2018

Myoma Imaging by Gynecologic Surgeons Training in Intraoperative Ultrasound Technique.

Bent Rachel E, Wilson Machelle D, Jacoby Vanessa L, Varon Shira, Parvataneni Ram, Saberi Naghmeh, Waetjen L Elaine

Клиническое исследованиеСтатьяМногоцентровое исследованиеПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

STUDY

OBJECTIVE

To compare preoperative transvaginal ultrasound (TVUS) and magnetic resonance imaging (MRI) with intraoperative ultrasound (IOUS) in surgeons first learning to use this technique.

DESIGN

A prospective study of IOUS accuracy for mapping the size and location of myomas compared with TVUS or MRI (Canadian Task Force classification II-2).

SETTING

Five University of California academic centers (Davis, Irvine, Los Angeles, San Diego, and San Francisco).

PATIENTS: Twenty-six premenopausal women seeking uterine-sparing surgical treatment of myomas. Eligible participants could have no more than 6 myomas ≥2 cm and <10 cm and a uterine size no larger than 16 weeks by pelvic examination.

INTERVENTIONS: Measurement of myomas by IOUS followed by radiofrequency ablation (RFA) of fibroids.

MEASUREMENTS AND MAIN

RESULTS

Eligible participants had to have imaging with TVUS or MRI within the last year to assess myoma characteristics. During the RFA operation, surgeons who had undergone a 1-day training on RFA and IOUS measured all myomas visualized with IOUS. Surgeons measured more myomas than were reported on MRI (12 on MRI and 16 on IOUS) or TVUS (41 on TVUS and 62 on IOUS) in all positions (anterior, posterior, lateral, and fundal). In particular, they identified more myomas <2 cm (4 on MRI, 9 on IOUS, 1 on TVUS, and 19 on IOUS). They located 2.3 times as many myomas in the anterior position as TVUS. For the myomas ≥2 cm identified by IOUS and MRI or IOUS and TVUS, there was no statistically significant difference in the mean myoma number or the mean myoma diameter measurements.

CONCLUSION

Surgeons first learning to use IOUS detect the same number of myomas ≥2 cm as identified by TVUS and MRI and find a greater number of myomas <2 cm on IOUS compared with radiologist-reported TVUS.

Для цитирования: Bent Rachel E, Wilson Machelle D, Jacoby Vanessa L, Varon Shira, Parvataneni Ram, Saberi Naghmeh, Waetjen L Elaine. Myoma Imaging by Gynecologic Surgeons Training in Intraoperative Ultrasound Technique.. Journal of minimally invasive gynecology. 2018. DOI: 10.1016/j.jmig.2018.11.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.