Journal of medical imaging and radiation oncology · 2019
Multi-observer contouring of male pelvic anatomy: Highly variable agreement across conventional and emerging structures of interest.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Roach Dale, Holloway Lois C, Jameson Michael G, Dowling Jason A, Kennedy Angel, Greer Peter B, Krawiec Michele, Rai Robba, Denham Jim, De Leon Jeremiah, Lim Karen, Berry Megan E, White Rohen T, Bydder Sean A, Tan Hendrick T, Croker Jeremy D, McGrath Alycea, Matthews John, Smeenk Robert J, Ebert Martin A
Аннотация
INTRODUCTION: This study quantified inter-observer contouring variations for multiple male pelvic structures, many of which are of emerging relevance for prostate cancer radiotherapy progression and toxicity response studies.
METHODS: Five prostate cancer patient datasets (CT and T2-weighted MR) were distributed to 13 observers for contouring. CT structures contoured included the clinical target volume (CTV), seminal vesicles, rectum, colon, bowel bag, bladder and peri-rectal space (PRS). MR contours included CTV, trigone, membranous urethra, penile bulb, neurovascular bundle and multiple pelvic floor muscles. Contouring variations were assessed using the intraclass correlation coefficient (ICC), Dice similarity coefficient (DSC), and multiple additional metrics.
RESULTS: Clinical target volume (CT and MR), bladder, rectum and PRS contours showed excellent inter-observer agreement (median ICC = 0.97; 0.99; 1.00; 0.95; 0.90, DSC = 0.83 ± 0.05; 0.88 ± 0.05; 0.93 ± 0.03; 0.81 ± 0.07; 0.80 ± 0.06, respectively). Seminal vesicle contours were more variable (ICC = 0.75, DSC = 0.73 ± 0.14), while colon and bowel bag contoured volumes were consistent (ICC = 0.97; 0.97), but displayed poor overlap (DSC = 0.58 ± 0.22; 0.67 ± 0.21). Smaller MR structures showed significant inter-observer variations, with poor overlap for trigone, membranous urethra, penile bulb, and left and right neurovascular bundles (DSC = 0.44 ± 0.22; 0.41 ± 0.21; 0.66 ± 0.21; 0.16 ± 0.17; 0.15 ± 0.15). Pelvic floor muscles recorded moderate to strong inter-observer agreement (ICC = 0.50-0.97), although large outlier variations were observed.
CONCLUSIONS: Inter-observer contouring variation was significant for multiple pelvic structures contoured on MR.
METHODS: Five prostate cancer patient datasets (CT and T2-weighted MR) were distributed to 13 observers for contouring. CT structures contoured included the clinical target volume (CTV), seminal vesicles, rectum, colon, bowel bag, bladder and peri-rectal space (PRS). MR contours included CTV, trigone, membranous urethra, penile bulb, neurovascular bundle and multiple pelvic floor muscles. Contouring variations were assessed using the intraclass correlation coefficient (ICC), Dice similarity coefficient (DSC), and multiple additional metrics.
RESULTS: Clinical target volume (CT and MR), bladder, rectum and PRS contours showed excellent inter-observer agreement (median ICC = 0.97; 0.99; 1.00; 0.95; 0.90, DSC = 0.83 ± 0.05; 0.88 ± 0.05; 0.93 ± 0.03; 0.81 ± 0.07; 0.80 ± 0.06, respectively). Seminal vesicle contours were more variable (ICC = 0.75, DSC = 0.73 ± 0.14), while colon and bowel bag contoured volumes were consistent (ICC = 0.97; 0.97), but displayed poor overlap (DSC = 0.58 ± 0.22; 0.67 ± 0.21). Smaller MR structures showed significant inter-observer variations, with poor overlap for trigone, membranous urethra, penile bulb, and left and right neurovascular bundles (DSC = 0.44 ± 0.22; 0.41 ± 0.21; 0.66 ± 0.21; 0.16 ± 0.17; 0.15 ± 0.15). Pelvic floor muscles recorded moderate to strong inter-observer agreement (ICC = 0.50-0.97), although large outlier variations were observed.
CONCLUSIONS: Inter-observer contouring variation was significant for multiple pelvic structures contoured on MR.