MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/jfprhc-2014-100917

Медицинская библиотека · The journal of family planning and reproductive health care · 2015

Lidocaine 10% spray to the cervix reduces pain during intrauterine device insertion: a double-blind randomised controlled trial.

Aksoy Hüseyin, Aksoy Ülkü, Ozyurt Sezin, Açmaz Gökhan, Babayigit Mustafa

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

Fear of pain during intrauterine device (IUD) insertion can be a barrier to widespread use of this safe and highly effective contraceptive method. Our objective was to determine the effectiveness of topical 10% lidocaine spray for pain control during IUD insertion.

METHODS

A total of 200 subjects with the request for IUD insertion were included in the study. The patients were randomly divided into two groups: lidocaine spray (n=100) and placebo (n=100). The pain experienced during the procedure was measured immediately after insertion by a standard Visual Analogue Scale (VAS) administered by a separate researcher with maintenance of allocation concealment.

RESULTS

The mean pain score during the procedure was 1.01±1.20 in the lidocaine spray group and 3.23±1.60 in the placebo spray group (p<0.001). Lidocaine spray treatment significantly lowered the overall procedural pain score compared with placebo.

CONCLUSIONS

Significant pain reduction during IUD insertion can be achieved by using 10% lidocaine spray alone. Lidocaine spray can be accepted as a non-invasive, easy to apply and more comfortable local anaesthetic method for IUD insertion.

TRIAL REGISTRATION NUMBER: NCT02020551.

Для цитирования: Aksoy Hüseyin, Aksoy Ülkü, Ozyurt Sezin, Açmaz Gökhan, Babayigit Mustafa. Lidocaine 10% spray to the cervix reduces pain during intrauterine device insertion: a double-blind randomised controlled trial.. The journal of family planning and reproductive health care. 2015. DOI: 10.1136/jfprhc-2014-100917.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.