m+Medelevator.RU
← Поиск публикаций
PLoS biology · 2025

Electrical Spinal Imaging: A noninvasive, high-resolution approach that enables electrophysiological mapping of the human spinal cord.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Gabrieli Giulio, Somervail Richard, Mouraux André, Leandri Massimo, Haggard Patrick, Iannetti Gian Domenico

Аннотация

The spinal cord is the key bridge between the brain and the body. However, scientific understanding of spinal cord function has historically been limited because noninvasive measures of its neural activity have proven exceptionally challenging. In this work, we describe an enhanced recording and analysis approach, Electrical Spinal Imaging (ESI), to obtain noninvasive, high-resolution images of the electrical activity of the human spinal cord. ESI is analytically simple, easy to implement, and data-driven: it does not involve template-based strategies prone to produce spurious signals. Using this approach, we provide a detailed description and physiological characterization of the spatiotemporal dynamics of the peripheral, spinal, and cortical activity elicited by somatosensory stimulation. We also demonstrate that attention modulates postsynaptic activity at spinal cord level. Our method has enabled five important insights regarding spinal cord activity. (1) We identified three distinct responses in the time domain: sP9, sN13, and sP22. (2) The sP9 is a traveling wave reflecting the afferent volley entering the spinal cord through the dorsal root. (3) In contrast, the sN13 and sP22 reflect segmental postsynaptic activity. (4) While the sP9 response is first seen on the dorsal electrodes ipsilateral to the stimulated side, the sN13 and sP22 were not lateralized with respect to the side of stimulation. (5) Unimodal attention strongly modulates the amplitude of the sP22, but not that of the sP9 and sN13 components. The proposed method offers critical insights into the spatiotemporal dynamics of somatosensory processing within the spinal cord, paving the way for precise noninvasive functional monitoring of the spinal cord in basic and clinical neurophysiology.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты