m+Medelevator.RU
← Поиск публикаций
Computers in biology and medicine · 2023

Weakly supervised segmentation of uterus by scribble labeling on endometrial cancer MR images.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ying Jie, Huang Wei, Fu Le, Yang Haima, Cheng Jiangzihao

Аннотация

Uterine segmentation of endometrial cancer MR images can be a valuable diagnostic tool for gynecologists. However, uterine segmentation based on deep learning relies on artificial pixel-level annotation, which is time-consuming, laborious and subjective. To reduce the dependence on pixel-level annotation, a method of weakly supervised uterine segmentation on endometrial cancer MRI slices is proposed, which only requires scribble label and is enhanced by pseudo-label technology, exponential geodesic distance loss and input disturbance strategy. Specifically, the limitations caused by the shortage of supervision are addressed by dynamically mixing the two outputs of the dual branch network to generate pseudo-labels, expanding supervision information and promoting mutual supervision training. On the other hand, considering the large difference of grayscale intensity between the uterus and surrounding tissues, the exponential geodesic distance loss is introduced to enhance the ability of the network to capture the edge of the uterus. Input disturbance strategies are incorporated to adapt to the flexible and variable characteristics of the uterus and further improve the segmentation performance of the network. The proposed method is evaluated on MRI images from 135 cases of endometrial cancer. Compared with other four weakly supervised segmentation methods, the performance of the proposed method is the best, whose mean DI, HD95, Recall, Precision, ADP are 92.8%, 11.632, 92.7%, 93.6%, 6.5% and increasing by 2.1%, 9.144, 0.6%, 2.4%, 2.9% respectively. The experimental results demonstrate that the proposed method is more effective than other weakly supervised methods and achieves similar performance as those fully supervised.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты