DOI 10.1016/j.ejmp.2021.08.009
Dosiomics-based prediction of radiation-induced hypothyroidism in nasopharyngeal carcinoma patients.
Аннотация
PURPOSE: To predict the incidence of radiation-induced hypothyroidism (RHT) in nasopharyngeal carcinoma (NPC) patients, dosiomics features based prediction models were established.
MATERIALS AND
METHODS
A total of 145 NPC patients treated with radiotherapy from January 2012 to January 2015 were included. Dosiomics features of the dose distribution within thyroid gland were extracted. The minimal-redundancy-maximal-relevance (mRMR) criterion was used to rank the extracted features and selected the most relevant features. Machine learning (ML) algorithms including logistic regression (LR), support vector machine (SVM), random forest (RF), and k-nearest neighbor (KNN) were utilized to establish prediction models, respectively. Nested sampling and hyper-tuning methods were adopted to train and validate the prediction models. The dosiomics-based (DO) prediction models were evaluated through comparing with the dose-volume factor-based (DV) models in terms of the area under the receiver operating characteristic (ROC) curve (AUC). The demographics factors (age and gender) were included in both DO model and DV model.
RESULTS
Age, V45 and 37 dosiomics features exhibited significant correlations with RHT in univariate analysis. For prediction performance, DO prediction models exhibited better results with the best AUC value 0.7 while DV prediction models 0.61. In DO prediction models, the AUC values displayed a trend from ascending to descending with the increasing of selected features. The highest AUC value was achieved when the number of selected features was 3. In DV prediction model, similar trend was not observed.
CONCLUSION
This study established a prediction model based on the dosiomics features with better performance than conventional dose-volume factors, leading to early predict the possible RHT among NPC patients who had received radiotherapy and take precaution measures for NPC patients.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.