m+Medelevator.RU
← Поиск публикаций
Peritoneal dialysis international : journal of the International Society for Peritoneal Dialysis · 2018

Systemic Endotoxin in Peritoneal Dialysis Patients.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Shendi Ali M, Davies Nathan, Davenport Andrew

Аннотация

Previous reports linked systemic endotoxemia in dialysis patients to increased markers of inflammation, cardiovascular disease, and mortality. Many peritoneal dialysis (PD) patients use acidic, hypertonic dialysates, which could potentially increase gut permeability, resulting in systemic endotoxemia. However, the results from studies measuring endotoxin in PD patients are discordant. We therefore measured systemic endotoxin in 55 PD outpatients attending for routine assessment of peritoneal membrane function; mean age 58.7 ± 16.4 years, 32 (58.2%) male, 21 (38.2%) diabetic, median duration of PD treatment 19.5 (13 - 31) months, 32 (58.2%) using 22.7 g/L dextrose dialysates, and 47 (85.5%) icodextrin. The median systemic endotoxin concentration was 0.0485 (0.0043 - 0.103) Eu/mL. We found no association between endotoxin levels and patient demographics, markers of inflammation, serum albumin, N-terminal pro-brain natriuretic peptide, extracellular volume measured by bioimpedance, blood pressure, PD prescriptions or peritoneal membrane transporter status, or medications. The measurement of endotoxin can be lowered by failure to effectively release protein-bound endotoxin prior to analysis and increased by contamination when taking blood samples and processing and storing the samples. Additionally, contamination with β-glucan from fungal cell walls and the use of different assays to analyze endotoxin can also give differing results. These factors may help to explain the disparate results reported in different studies. Our study would suggest that exposure to standard peritoneal dialysates does not substantially increase systemic endotoxin. However, until endotoxin assays can measure free and bound endotoxin separately, the role of endotoxin causing inflammation in PD patients remains to be determined.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты