Chihara Naoto, Suzuki Hideyuki, Sukegawa Makoto, Watanabe Masanori, Oyama Rina, Shimizu Takao, Uchida Eiji
Аннотация
INTRODUCTION: The laparoscopic transabdominal preperitoneal approach requires peritoneal closure and technically skilled knotting. We have started to use a barbed running suturing device (V-Loc 180) without knotting for transabdominal preperitoneal repair of hernias. This study aimed to determine whether using V-Loc 180 was safe and shortened the time for laparoscopic peritoneal closure.
METHODS: Between December 2010 and February 2017, 3-0 V-Loc 180 and a multifilament absorbable running suture (3-0 Vicryl) were used for three-port transabdominal preperitoneal repair of inguinal hernia in 363 cases. Data including peritoneal closure time and the complications were retrospectively recorded.
RESULTS: Factors identified as significantly prolonging the peritoneal closure time were the hernia side (P = 0.0269), the type of hernia (P = 0.001), the suture device used (P < 0.0001), and the surgeon's experience (P < 0.0001). Use of the barbed suture was associated with a significantly shorter peritoneal closure time than the multifilament suture (mean closure time: 10.2 and 12.7 min, respectively). While there were no postoperative complications in the barbed suture group, there were two cases (1.9%) of postoperative complications in the multifilament suture group (P = 0.0272).
CONCLUSION: We demonstrated that the use of the barbed suturing device for laparoscopic peritoneal closure was safe and feasible.
METHODS: Between December 2010 and February 2017, 3-0 V-Loc 180 and a multifilament absorbable running suture (3-0 Vicryl) were used for three-port transabdominal preperitoneal repair of inguinal hernia in 363 cases. Data including peritoneal closure time and the complications were retrospectively recorded.
RESULTS: Factors identified as significantly prolonging the peritoneal closure time were the hernia side (P = 0.0269), the type of hernia (P = 0.001), the suture device used (P < 0.0001), and the surgeon's experience (P < 0.0001). Use of the barbed suture was associated with a significantly shorter peritoneal closure time than the multifilament suture (mean closure time: 10.2 and 12.7 min, respectively). While there were no postoperative complications in the barbed suture group, there were two cases (1.9%) of postoperative complications in the multifilament suture group (P = 0.0272).
CONCLUSION: We demonstrated that the use of the barbed suturing device for laparoscopic peritoneal closure was safe and feasible.