DOI 10.1177/1753465816637053

Медицинская библиотека · Therapeutic advances in respiratory disease · 2016

Diagnostic yield of electromagnetic navigational bronchoscopy.

Al-Jaghbeer Mohammed, Marcus Mathew, Durkin Martin, McGuire Franklin R, Iftikhar Imran H

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Peripheral lung nodules (PLNs) are a common and diagnostically challenging finding. Electronavigational bronchoscopy (ENB) is used to increase the diagnostic yield and is considered safe. Multiple factors have been correlated with a better diagnostic yield. We sought to assess the effect of nodule characteristics and prior workup on the diagnostic yield in ENB.

METHODS

This was a retrospective chart review of 98 ENB procedures in a community referral center. Two investigators reviewed patients' charts and images independently. Multiple logistic regression analyses was used to determine if factors such as bronchus sign, ground glass opacification (GGO), distance from pleura, prior use of endobronchial ultrasound (EBUS) and positron emission tomography (PET) had an impact on the diagnostic yield.

RESULTS

We evaluated 98 ENBs performed in 92 patients. Most of the lesions were in the upper lobes. The diagnostic yield was 60%. A PET scan was performed prior to ENB in 47% of cases. EBUS was performed in 24% of cases. Bronchus sign was present in 60% of cases and GGO in only 6% of nodules. The odds ratio for diagnostic yield with a bronchus sign was 1.89 [95% confidence interval (CI): 0.83-4.33] and with nodules showing GGO characteristics it was 4.51 (95% CI: 0.51-39.68). Pneumothorax occurred in 6% of cases.

CONCLUSION

In our cohort, diagnostic yield was 60% with a 6% pneumothorax rate. A suggestive trend for the presence of bronchus sign on computed tomography scan, albeit statistically nonsignificant, as a predictor for improved diagnostic yield needs to be validated in a larger cohort.

Для цитирования: Al-Jaghbeer Mohammed, Marcus Mathew, Durkin Martin, McGuire Franklin R, Iftikhar Imran H. Diagnostic yield of electromagnetic navigational bronchoscopy.. Therapeutic advances in respiratory disease. 2016. DOI: 10.1177/1753465816637053.