Diseases of the colon and rectum · 2022
Stapled Antimesenteric Functional End-to-End Anastomosis Following Intestinal Resection for Crohn's Disease.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Duan Ming, Wu Enhao, Xi Yue, Wu You, Gong Jianfeng, Zhu Weiming, Li Yi
Аннотация
BACKGROUND: Anastomotic recurrence after bowel resection is problematic in patients with Crohn's disease. Antimesenteric functional end-to-end handsewn (Kono-S) anastomosis is associated with a low risk of anastomotic recurrence in patients with Crohn's disease.
IMPACT OF INNOVATION: Kono-S anastomosis is effective but may be time-consuming. This study aimed to describe stapled antimesenteric functional end-to-end anastomosis for patients with Crohn's disease.
TECHNOLOGY MATERIALS AND METHODS: The mesentery of the affected bowel segment was divided. A 5-cm-wide stapled functional end-to-end anastomosis was performed approximately 6 cm from the affected segment. The bowel was divided transversely exactly 90° to the intestinal lumen and the mesentery, and a supporting column was then constructed.
PRELIMINARY RESULTS: From January 2018 to June 2021, 17 stapled antimesenteric functional end-to-end anastomoses were performed. The mean operative time was 106 (range, 80-135) minutes, and the time to construct the stapled antimesenteric functional end-to-end anastomosis was 21 (range, 18-28) minutes. The mean follow-up time was 8.9 (range, 1-15) months. In total, 10 patients underwent surveillance endoscopy. The average Rutgeerts score was 0.8 (range, 0-4), and the incidence of endoscopic recurrence was 11.8%. No postoperative mortality or anastomotic leakage was observed.
CONCLUSION: Stapled antimesenteric functional end-to-end anastomosis may be a safe and time-saving procedure for patients with Crohn's disease.
FUTURE DIRECTIONS: Further prospective studies with a large sample size are warranted.
IMPACT OF INNOVATION: Kono-S anastomosis is effective but may be time-consuming. This study aimed to describe stapled antimesenteric functional end-to-end anastomosis for patients with Crohn's disease.
TECHNOLOGY MATERIALS AND METHODS: The mesentery of the affected bowel segment was divided. A 5-cm-wide stapled functional end-to-end anastomosis was performed approximately 6 cm from the affected segment. The bowel was divided transversely exactly 90° to the intestinal lumen and the mesentery, and a supporting column was then constructed.
PRELIMINARY RESULTS: From January 2018 to June 2021, 17 stapled antimesenteric functional end-to-end anastomoses were performed. The mean operative time was 106 (range, 80-135) minutes, and the time to construct the stapled antimesenteric functional end-to-end anastomosis was 21 (range, 18-28) minutes. The mean follow-up time was 8.9 (range, 1-15) months. In total, 10 patients underwent surveillance endoscopy. The average Rutgeerts score was 0.8 (range, 0-4), and the incidence of endoscopic recurrence was 11.8%. No postoperative mortality or anastomotic leakage was observed.
CONCLUSION: Stapled antimesenteric functional end-to-end anastomosis may be a safe and time-saving procedure for patients with Crohn's disease.
FUTURE DIRECTIONS: Further prospective studies with a large sample size are warranted.