Head and neck elevation beyond the sniffing position improves laryngeal view in cases of difficult direct laryngoscopy.

Schmitt Hubert J, Mang Harald

СтатьяПеревод пока не подготовлен

Аннотация

STUDY

OBJECTIVE

To determine the influence of head and neck elevation beyond the "sniffing position" during difficult direct laryngoscopy.

DESIGN

Prospective case series, with each patient serving as her or his control.

SETTING

University hospital.

PATIENTS: 21 patients scheduled for general anesthesia and endotracheal intubation, all of whom presented with a laryngoscopic grade III view (Cormack & Lehane) during direct laryngoscopy in the sniffing position.

INTERVENTIONS: An assistant applied external laryngeal pressure with his left hand and elevated the patient's head and neck above the sniffing position with his right hand to improve laryngeal view.

MEASUREMENTS AND MAIN

RESULTS

External laryngeal pressure and elevation of head and neck improved the laryngoscopic view in 19 of 21 patients to grade II (p = 0.001, Wilcoxon signed rank test). Beyond that, laryngoscopy with the neck maximally elevated enabled visualization of parts of the cords in six patients (30%).

CONCLUSIONS

Elevation of the head and neck beyond the sniffing position may improve visualization of glottic structures in cases of difficult direct laryngoscopy, leading to better intubation performance.

Для цитирования: Schmitt Hubert J, Mang Harald. Head and neck elevation beyond the sniffing position improves laryngeal view in cases of difficult direct laryngoscopy.. Journal of clinical anesthesia. 2002. DOI: 10.1016/s0952-8180(02)00368-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.