MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.joen.2024.01.022

Медицинская библиотека · Journal of endodontics · 2024

External Validation of the Effect of the Combined Use of Object Detection for the Classification of the C-Shaped Canal Configuration of the Mandibular Second Molar in Panoramic Radiographs: A Multicenter Study.

Yang Sujin, Kim Kee-Deog, Kise Yoshitaka, Nozawa Michihito, Mori Mizuho, Takata Natsuho, Katsumata Akitoshi, Ariji Yoshiko, Park Wonse, Ariji Eiichiro

СтатьяМногоцентровое исследованиеВалидационное исследованиеПеревод пока не подготовлен

Аннотация

INTRODUCTION

The purposes of this study were to evaluate the effect of the combined use of object detection for the classification of the C-shaped canal anatomy of the mandibular second molar in panoramic radiographs and to perform an external validation on a multicenter dataset.

METHODS

The panoramic radiographs of 805 patients were collected from 4 institutes across two countries. The CBCT data of the same patients were used as "Ground-truth". Five datasets were generated: one for training and validation, and 4 as external validation datasets. Workflow 1 used manual cropping to prepare the image patches of mandibular second molars, and then classification was performed using EfficientNet. Workflow 2 used two combined methods with a preceding object detection (YOLOv7) performed for automated image patch formation, followed by classification using EfficientNet. Workflow 3 directly classified the root canal anatomy from the panoramic radiographs using the YOLOv7 prediction outcomes. The classification performance of the 3 workflows was evaluated and compared across 4 external validation datasets.

RESULTS

For Workflows 1, 2, and 3, the area under the receiver operating characteristic curve (AUC) values were 0.863, 0.861, and 0.876, respectively, for the AGU dataset; 0.935, 0.945, and 0.863, respectively, for the ASU dataset; 0.854, 0.857, and 0.849, respectively, for the ODU dataset; and 0.821, 0.797, and 0.831, respectively, for the ODU low-resolution dataset. No significant differences existed between the AUC values of Workflows 1, 2, and 3 across the 4 datasets.

CONCLUSIONS

The deep learning systems of the 3 workflows achieved significant accuracy in predicting the C-shaped canal in mandibular second molars across all test datasets.

Для цитирования: Yang Sujin, Kim Kee-Deog, Kise Yoshitaka, Nozawa Michihito, Mori Mizuho, Takata Natsuho, Katsumata Akitoshi, Ariji Yoshiko, Park Wonse, Ariji Eiichiro. External Validation of the Effect of the Combined Use of Object Detection for the Classification of the C-Shaped Canal Configuration of the Mandibular Second Molar in Panoramic Radiographs: A Multicenter Study.. Journal of endodontics. 2024. DOI: 10.1016/j.joen.2024.01.022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.