m+Medelevator.RU
← Поиск публикаций
The Journal of prosthetic dentistry · 2024

Comparison of accuracy between single posterior immediate and delayed implants placed using computer guided implant surgery and a digital laser printed surgical guide: A clinical investigation.

СтатьяСравнительное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Mittal Sankalp, Kaurani Pragati, Goyal Ritika

Аннотация

STATEMENT OF PROBLEM: The congruence of surgical implant placement with the preplanned position is important for anatomic and prosthetic precision, minimal complications, and increased longevity. The influence of implant placement timing on the surgical deviations in single posterior implants is unclear.

PURPOSE: The purpose of this clinical study was to compare deviations between preplanned and single posterior immediate and delayed implants placed using computer-guided digital light processing (DLP) surgical guides fabricated using intraoral scanning and cone beam computed tomography (CBCT).

MATERIAL AND METHODS: Implant surgery was performed on 24 participants requiring single immediate or delayed implants in the posterior maxillary and mandibular regions, for which the surgical site data were obtained from CBCT and intraoral scanning. Subsequently, virtual implant planning and DLP surgical guides were fabricated. Preimplant and postimplant placement CBCT scans were overlapped, and mean deviations for the immediate and delayed implant groups were calculated. The groups were compared with unpaired t tests (α=.05).

RESULTS: A total of 24 implants were placed, 12 in each group. In participants who received immediate implant placement, the mean ±standard deviation angular deviation, linear deviation at shoulder, linear deviation at apex, and vertical deviation were 1.03 ±0.70 degrees, 0.26 ±0.30 mm, 0.23 ±0.24 mm, and 0.39 ± 0.34 mm, respectively. In participants who received delayed implant treatment, the deviations were 0.53 ±0.60 degrees, 0.15 ±0.18 mm, 0.25 ±0.33 mm, and 0.17 ±0.10 mm, respectively. Significant differences between the 2 groups were found in the vertical deviation (P<.05).

CONCLUSIONS: The timing of the single posterior placement was associated with different deviations in the vertical direction. All deviations obtained were below the recommended values. DLP surgical guides fabricated from intraoral and CBCT scans provided accurate implant placement in immediate and delayed single posterior implants.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты