Clinical oral investigations · 2024
Analysis of ultra-short implants with different angulations: a retrospective case-control study with 2 to 9 years of follow-up.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Malchiodi Luciano, Fiorino Antonino, Merlino Lisa, Cucchi Alessandro, Zotti Francesca, Nocini Pier Francesco
Аннотация
OBJECTIVES: Does the angulation of ultrashort implants influence the stability of the peri-implant bone? The present study aimed to evaluate the effectiveness of non-axial ultrashort implants after 2 to 9 years of follow-up in resorbed alveolar ridges.
MATERIALS AND METHODS: All partially edentulous patients with ultrashort implants (< 6 mm) used in the posterior region of an atrophic mandible or maxilla, to support partial dentures in conjunction with standard implants, were included in this study. Peri-implant bone loss, success and survival rates, crestal bone levels, crown-to-implant ratio and implant angulation were measured for each implant. Implants were divided into two groups: straight implants with angulation < 17° (control group) and tilted implants with angulation > 17° (test group). Statistical analysis was used to find any significant differences between the two study groups and to investigate significant linear correlations among all the variables (p = 0.05).
RESULTS: A total of 42 ultrashort implants with a mean of 4 years of follow-up were included: 20 ultrashort axially loaded implants and 22 tilted implants. Mean crestal bone levels from baseline loading to maximum follow-up did not reveal statistical differences in regard to PBL; mean success and survival rates were 100% in all groups.
CONCLUSIONS: PBL, success and survival rates of axial ultrashort implants and tilted ultrashort implants are comparable to those of conventional implants.
CLINICAL RELEVANCE: This retrospective study revealed that ultrashort implants, even when placed with an angulation > 17°, can safely be used to support partial fixed prostheses. Further prospective clinical studies with larger samples and prospective design are needed to confirm these findings.
MATERIALS AND METHODS: All partially edentulous patients with ultrashort implants (< 6 mm) used in the posterior region of an atrophic mandible or maxilla, to support partial dentures in conjunction with standard implants, were included in this study. Peri-implant bone loss, success and survival rates, crestal bone levels, crown-to-implant ratio and implant angulation were measured for each implant. Implants were divided into two groups: straight implants with angulation < 17° (control group) and tilted implants with angulation > 17° (test group). Statistical analysis was used to find any significant differences between the two study groups and to investigate significant linear correlations among all the variables (p = 0.05).
RESULTS: A total of 42 ultrashort implants with a mean of 4 years of follow-up were included: 20 ultrashort axially loaded implants and 22 tilted implants. Mean crestal bone levels from baseline loading to maximum follow-up did not reveal statistical differences in regard to PBL; mean success and survival rates were 100% in all groups.
CONCLUSIONS: PBL, success and survival rates of axial ultrashort implants and tilted ultrashort implants are comparable to those of conventional implants.
CLINICAL RELEVANCE: This retrospective study revealed that ultrashort implants, even when placed with an angulation > 17°, can safely be used to support partial fixed prostheses. Further prospective clinical studies with larger samples and prospective design are needed to confirm these findings.