m+Medelevator.RU
← Поиск публикаций
Experimental and molecular pathology · 2015

Multi-center evaluation of the novel fully-automated PCR-based Idylla™ BRAF Mutation Test on formalin-fixed paraffin-embedded tissue of malignant melanoma.

Оценочное исследованиеСтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Melchior Linea, Grauslund Morten, Bellosillo Beatriz, Montagut Clara, Torres Erica, Moragón Ester, Micalessi Isabel, Frans Johan, Noten Veerle, Bourgain Claire, Vriesema Renske, van der Geize Robert, Cokelaere Kristof, Vercooren Nancy, Crul Katrien, Rüdiger Thomas, Buchmüller Diana, Reijans Martin, Jans Caroline

Аннотация

The advent of BRAF-targeted therapies led to increased survival in patients with metastatic melanomas harboring a BRAF V600 mutation (implicated in 46-48% of malignant melanomas). The Idylla(™) System (Idylla(™)), i.e., the real-time-PCR-based Idylla(™) BRAF Mutation Test performed on the fully-automated Idylla(™) platform, enables detection of the most frequent BRAF V600 mutations (V600E/E2/D, V600K/R/M) in tumor material within approximately 90 min and with 1% detection limit. Idylla(™) performance was determined in a multi-center study by analyzing BRAF mutational status of 148 archival formalin-fixed paraffin-embedded (FFPE) tumor samples from malignant melanoma patients, and comparing Idylla(™) results with assessments made by commercial or in-house routine diagnostic methods. Of the 148 samples analyzed, Idylla(™) initially recorded 7 insufficient DNA input calls and 15 results discordant with routine method results. Further analysis learned that the quality of 8 samples was insufficient for Idylla(™) testing, 1 sample had an invalid routine test result, and Idylla(™) results were confirmed in 10 samples. Hence, Idylla(™) identified all mutations present, including 7 not identified by routine methods. Idylla(™) enables fully automated BRAF V600 testing directly on FFPE tumor tissue with increased sensitivity, ease-of-use, and much shorter turnaround time compared to existing diagnostic tests, making it a tool for rapid, simple and highly reliable analysis of therapeutically relevant BRAF mutations, in particular for diagnostic units without molecular expertise and infrastructure.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты