m+Medelevator.RU
← Поиск публикаций
The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians · 2010

Vascularization of the placenta and the sub-placental myometrium: feasibility and reproducibility of a three-dimensional power Doppler ultrasound quantification technique. A pilot study.

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Morel Olivier, Grangé Gilles, Fresson Jeanne, Schaaps Jean P, Foidart Jean M, Cabrol Dominique, Tsatsaris Vassilis

Аннотация

OBJECTIVE: To assess the feasibility of placental and myometrial vascularization quantification using 3D power Doppler ultrasonography.

METHODS: 3D standardized acquisition was performed in the mid part of the utero-placental unit, once, in 38 patients undergoing normal pregnancies between 15 and 39 weeks. Vascularization parameters (VI, FI, and VFI) of placentae and myometrium were measured. Intra and inter-observer, as well as inter-acquisition reproducibility were evaluated.

RESULTS: Intra-class Correlation Coefficient of vascularization measurements were at least 0.94 for intra-observer, 0.92 for inter-observer, and 0.56 for inter-acquisition reproducibility. There was no significant difference for placental measurements for VI, FI and VFI between the second trimester and the third trimester pregnancies. Concerning the myometrium, we observed no significant difference between second and third trimester for FI. However, VI (28.090 vs. 19.374) and VFI (17.691 vs. 11.336) was significantly lower in the third trimester (p < 0.01).

CONCLUSION: 3D quantification of placental and myometrial vascular parameters is feasible with a high intra and inter-observer reproducibility. Evaluating a potential myometrial vascular impairment appears to be as relevant as studying the placenta alone and might be of great clinical interest. We believe that this technique should therefore be evaluated in clinical observational studies.