MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.fertnstert.2008.07.1746

Медицинская библиотека · Fertility and sterility · 2008

Two-dimensional HyCoSy with contrast tuned imaging technology and a second-generation contrast media for the assessment of tubal patency in an infertility program.

Lanzani Chiara, Savasi Valeria, Leone Francesco P G, Ratti Martina, Ferrazzi Enrico

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To compare the efficiency of hysterosalpingo-contrast-sonography performed with air and saline (Hydro-HyCoSy) with HyCoSy performed with contrast media (SonoVue) and contrast-tuned imaging technology (CnTI-SonoVue-HyCoSy) considering hysterosalpingography (HSG) and laparoscopy (LPS) as reference tests and to evaluate the learning curve of this procedure.

DESIGN

Retrospective study.

SETTING

Reproductive unit of a university hospital.

PATIENT(S): Forty-two infertile female patients.

INTERVENTION(S): HyCoSy were performed with a 2.4-mm intrauterine catheter. Patients underwent HSG or LPS as controls.

MAIN OUTCOME MEASURE(S): Mean age, sensitivity, specificity, positive and negative predictive value, kappa value, and diagnostic accuracy were evaluated for statistical analysis.

RESULT(S): Sensitivity, specificity, and positive and negative predictive values of Hydro-HyCoSy were 91%, 71%, 55%, and 95%, respectively, while for CnTI-SonoVue-HyCoSy they were 87%, 84%, 69%, and 94%. The diagnostic accuracy of Hydro-HyCoSy and of CnTI-SonoVue-HyCoSy were 77% and 85%, with a Cohen's kappa of 0.52 and 0.66, respectively. CnTI-SonoVue-HyCoSy does not require a learning curve period.

CONCLUSION(S): CnTI-SonoVue-HyCoSy is more accurate than Hydro-HyCoSy for the assessment of fallopian tubes. The very high normal predictive value of Hydro-HyCoSy suggests that this procedure could be performed as a screening examination, whereas CnTI-SonoVue-HyCoSy could be used as a second-step technique.

Для цитирования: Lanzani Chiara, Savasi Valeria, Leone Francesco P G, Ratti Martina, Ferrazzi Enrico. Two-dimensional HyCoSy with contrast tuned imaging technology and a second-generation contrast media for the assessment of tubal patency in an infertility program.. Fertility and sterility. 2008. DOI: 10.1016/j.fertnstert.2008.07.1746.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.