MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1258/ijsa.2008.008429

Медицинская библиотека · International journal of STD & AIDS · 2009

Breakage of arm of Multiload intrauterine device during removal.

Mohanty K

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

We report a case of intrauterine device (IUD) removal five years after its insertion which was broken during the removal procedure. One of the arms of the IUD remained inside the uterus. We allowed three months for spontaneous expulsion. When this did not happen, we proceeded with a hysteroscopic removal. Because of its embebbed position in the myometrium this could not be removed during hysteroscopy and finally it was left in situ. The patient was monitored every three months for a period of 12 months. There was no problem. We report this case because doctors may find it necessary to remove the IUD in certain situations and be aware of such a breakage and various precautions to prevent this.

Для цитирования: Mohanty K. Breakage of arm of Multiload intrauterine device during removal.. International journal of STD & AIDS. 2009. DOI: 10.1258/ijsa.2008.008429.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.