Oral oncology · 2022
Improved accuracy of auto-segmentation of organs at risk in radiotherapy planning for nasopharyngeal carcinoma based on fully convolutional neural network deep learning.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Peng Yinglin, Liu Yimei, Shen Guanzhu, Chen Zijie, Chen Meining, Miao Jingjing, Zhao Chong, Deng Jincheng, Qi Zhenyu, Deng Xiaowu
Аннотация
OBJECTIVE: We examined a modified encoder-decoder architecture-based fully convolutional neural network, OrganNet, for simultaneous auto-segmentation of 24 organs at risk (OARs) in the head and neck, followed by validation tests and evaluation of clinical application.
MATERIALS AND METHODS: Computed tomography (CT) images from 310 radiotherapy plans were used as the experimental data set, of which 260 and 50 were used as the training and test sets, respectively. An improved U-Net architecture was established by introducing a batch normalization layer, residual squeeze-and-excitation layer, and unique organ-specific loss function for deep learning training. The performance of the trained network model was evaluated by comparing the manual-delineation and the STAPLE contour of 10 physicians from different centers.
RESULTS: Our model achieved good segmentation in all 24 OARs in nasopharyngeal cancer radiotherapy plan CT images, with an average Dice similarity coefficient of 83.75%. Specifically, the mean Dice coefficients in large-volume organs (brainstem, spinal cord, left/right parotid glands, left/right temporal lobes, and left/right mandibles) were 84.97% - 95.00%, and in small-volume organs (pituitary, lens, optic nerve, and optic chiasma) were 55.46% - 91.56%. respectively. Using the STAPLE contours as standard contour, the OrganNet achieved comparable or better DICE in organ segmentation then that of the manual-delineation as well.
CONCLUSION: The established OrganNet enables simultaneous automatic segmentation of multiple targets on CT images of the head and neck radiotherapy plans, effectively improves the accuracy of U-Net based segmentation for OARs, especially for small-volume organs.
MATERIALS AND METHODS: Computed tomography (CT) images from 310 radiotherapy plans were used as the experimental data set, of which 260 and 50 were used as the training and test sets, respectively. An improved U-Net architecture was established by introducing a batch normalization layer, residual squeeze-and-excitation layer, and unique organ-specific loss function for deep learning training. The performance of the trained network model was evaluated by comparing the manual-delineation and the STAPLE contour of 10 physicians from different centers.
RESULTS: Our model achieved good segmentation in all 24 OARs in nasopharyngeal cancer radiotherapy plan CT images, with an average Dice similarity coefficient of 83.75%. Specifically, the mean Dice coefficients in large-volume organs (brainstem, spinal cord, left/right parotid glands, left/right temporal lobes, and left/right mandibles) were 84.97% - 95.00%, and in small-volume organs (pituitary, lens, optic nerve, and optic chiasma) were 55.46% - 91.56%. respectively. Using the STAPLE contours as standard contour, the OrganNet achieved comparable or better DICE in organ segmentation then that of the manual-delineation as well.
CONCLUSION: The established OrganNet enables simultaneous automatic segmentation of multiple targets on CT images of the head and neck radiotherapy plans, effectively improves the accuracy of U-Net based segmentation for OARs, especially for small-volume organs.