Head & neck · 2022
Detection of increased intracranial pressure in trans-oral robotic thyroidectomy using optic nerve sheath diameter measurement.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Lim Hyunyoung, Kim Eugene, Kim Soo Yeon, Kim Ji-Yoon, Jung Yundo, Lee Tagkeun, Kim Nayeon, Tae Kyung
Аннотация
BACKGROUND: During transoral robot-assisted thyroidectomy, there is a risk of increasing intracranial pressure because the site of CO2 insufflation is narrow and close to the brain.
METHODS: We analyzed the pre- to post-CO2 neck insufflation change in the optic nerve sheath diameter during transoral robot-assisted thyroidectomy. Changes in vital-signs, airway pressure, and arterial carbon dioxide pressure were analyzed along with postoperative complications.
RESULTS: Among the 30 participants, the post-CO2 inflation mean optic nerve sheath diameter (5.64 ± 0.54 mm) was higher than the pre-induction diameter (4.81 ± 0.37 mm) with a mean difference of 0.83 (95% CI, 0.69-0.97; p < 0.001), but returned to baseline after CO2 deflation in most cases. One participant had sustained increased optic nerve sheath diameter (6.35 mm) associated with severe new-onset postoperative headache.
CONCLUSION: Transient elevation in the intracranial pressure during low-pressure CO2 neck insufflation in the transoral robot-assisted thyroidectomy did not appear to adversely affect patients.
METHODS: We analyzed the pre- to post-CO2 neck insufflation change in the optic nerve sheath diameter during transoral robot-assisted thyroidectomy. Changes in vital-signs, airway pressure, and arterial carbon dioxide pressure were analyzed along with postoperative complications.
RESULTS: Among the 30 participants, the post-CO2 inflation mean optic nerve sheath diameter (5.64 ± 0.54 mm) was higher than the pre-induction diameter (4.81 ± 0.37 mm) with a mean difference of 0.83 (95% CI, 0.69-0.97; p < 0.001), but returned to baseline after CO2 deflation in most cases. One participant had sustained increased optic nerve sheath diameter (6.35 mm) associated with severe new-onset postoperative headache.
CONCLUSION: Transient elevation in the intracranial pressure during low-pressure CO2 neck insufflation in the transoral robot-assisted thyroidectomy did not appear to adversely affect patients.