Combining Optical Coherence Tomography and Optical Coherence Tomography Angiography Longitudinal Data for the Detection of Visual Field Progression in Glaucoma.

Kamalipour Alireza, Moghimi Sasan, Khosravi Pooya, Mohammadzadeh Vahid, Nishida Takashi, Micheletti Eleonora, Wu Jo-Hsuan, Mahmoudinezhad Golnoush, Li Elizabeth H F, Christopher Mark, Zangwill Linda, Javidi Tara, Weinreb Robert N

СтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

PURPOSE: To use longitudinal optical coherence tomography (OCT) and OCT angiography (OCTA) data to detect glaucomatous visual field (VF) progression with a supervised machine learning approach.

DESIGN

Prospective cohort study.

METHODS

One hundred ten eyes of patients with suspected glaucoma (33.6%) and patients with glaucoma (66.4%) with a minimum of 5 24-2 VF tests and 3 optic nerve head and macula images over an average follow-up duration of 4.1 years were included. VF progression was defined using a composite measure including either a "likely progression event" on Guided Progression Analysis, a statistically significant negative slope of VF mean deviation or VF index, or a positive pointwise linear regression event. Feature-based gradient boosting classifiers were developed using different subsets of baseline and longitudinal OCT and OCTA summary parameters. The area under the receiver operating characteristic curve (AUROC) was used to compare the classification performance of different models.

RESULTS

VF progression was detected in 28 eyes (25.5%). The model with combined baseline and longitudinal OCT and OCTA parameters at the global and hemifield levels had the best classification accuracy to detect VF progression (AUROC = 0.89). Models including combined OCT and OCTA parameters had higher classification accuracy compared with those with individual subsets of OCT or OCTA features alone. Including hemifield measurements significantly improved the models' classification accuracy compared with using global measurements alone. Including longitudinal rates of change of OCT and OCTA parameters (AUROCs = 0.80-0.89) considerably increased the classification accuracy of the models with baseline measurements alone (AUROCs = 0.60-0.63).

CONCLUSIONS

Longitudinal OCTA measurements complement OCT-derived structural metrics for the evaluation of functional VF loss in patients with glaucoma.

Для цитирования: Kamalipour Alireza, Moghimi Sasan, Khosravi Pooya, Mohammadzadeh Vahid, Nishida Takashi, Micheletti Eleonora, Wu Jo-Hsuan, Mahmoudinezhad Golnoush, Li Elizabeth H F, Christopher Mark, Zangwill Linda, Javidi Tara, Weinreb Robert N. Combining Optical Coherence Tomography and Optical Coherence Tomography Angiography Longitudinal Data for the Detection of Visual Field Progression in Glaucoma.. American journal of ophthalmology. 2022. DOI: 10.1016/j.ajo.2022.10.016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.