Reconstruction of occluded pelvis markers during marker-based motion capture with industrial exoskeletons.

Johns Jasper, Bender A, Glitsch U, Schmidt-Bleek L, Dymke J, Brandl C, Damm P, Heinrich K

СтатьяПеревод пока не подготовлен

Аннотация

Industrial back support exoskeletons are a promising solution to alleviate lumbar musculoskeletal strain. Due to the complexity of spinal loading, evaluation of EMG data alone has been considered insufficient to assess their support effects, and complementary kinematic and dynamic data are required. However, the acquisition of marker-based kinematics is challenging with exoskeletons, as anatomical reference points, particularly on the pelvis, are occluded by exoskeleton structures. The aim of this study was therefore to develop and validate a method to reliably reconstruct the occluded pelvic markers. The movement data of six subjects, for whom pelvic markers could be placed while wearing an exoskeleton, were used to test the reconstructions and compare them to anatomical landmarks during lifting, holding and walking. Two separate approaches were used for the reconstruction. One used a reference coordinate system based on only exoskeleton markers (EXO), as has been suggested in the literature, while our proposed method adds a technical marker in the lumbar region (LUMB) to compensate for any shifting between exoskeleton and pelvis. Reconstruction with EXO yielded on average an absolute linear deviation of 54 mm ± 16 mm (mean ± 1SD) compared to anatomical markers. The additional marker in LUMB reduced mean deviations to 14 mm ± 7 mm (mean ± 1SD). Both methods were compared to reference values from the literature for expected variances due to marker placement and soft tissue artifacts. For LUMB 99% of reconstructions were within the defined threshold of 24 mm ±9 mm while for EXO 91% were outside.

Для цитирования: Johns Jasper, Bender A, Glitsch U, Schmidt-Bleek L, Dymke J, Brandl C, Damm P, Heinrich K. Reconstruction of occluded pelvis markers during marker-based motion capture with industrial exoskeletons.. Computer methods in biomechanics and biomedical engineering. 2024. DOI: 10.1080/10255842.2024.2350592.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.