DOI 10.1016/0003-4975(95)00752-0
Staging non-small cell lung cancer by whole-body positron emission tomographic imaging.
Аннотация
BACKGROUND
A need exists for an accurate, noninvasive means of staging non-small cell lung cancer.
METHODS
A prospective evaluation of regional and whole-body positron emission tomography (PET) imaging for staging lung cancer was carried out in 99 patients. Mediastinal PET and computed tomography findings were compared with results of surgical staging in 76 patients. Those PET and computed tomography findings that indicated possible distant metastasis were compared with biopsy results and the results of clinical and imaging follow-up.
RESULTS
Sensitivity and specificity for the diagnosis of N2 disease were 83% and 94% for PET and 63% and 73% for computed tomography, respectively. Positron emission tomography showed previously unsuspected distant metastasis in 11 patients (11%), with no demonstrated false-positive results. Normal PET findings were obtained at distant sites of computed tomography abnormality in 19 patients (19%). Clinical and imaging follow-up in 14 of these patients showed no evidence of metastasis. In 1 case, the PET result proved to be falsely negative.
CONCLUSIONS
Imaging with PET was more accurate than computed tomography for diagnosis of mediastinal and distant metastasis. Detection of unsuspected metastatic disease by PET may permit reduction in the number of thoracotomies performed for nonresectable disease.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.