DOI 10.1002/jso.10078

Медицинская библиотека · Journal of surgical oncology · 2002

Validating the performance of the mammary sentinel lymph node team.

Euhus David M, Peters George N, Leitch A Marilyn, Saboorian Hossein, Mathews Dana, Erdman William, Anglin Beth, Huth James

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVES

The mammary sentinel lymph node (SLN) procedure has the potential to improve the accuracy and lower the morbidity of axillary staging in breast cancer patients, but results are closely linked to experience and can vary widely between institutions. Standardized performance measures need to be established in order to optimize the transition to SLN biopsy only.

METHODS

Performance data were prospectively collected for the first 156 mammary SLN procedures performed by three surgeons in our institution.

RESULTS

Seventy-five cases were required to achieve an SLN visualization rate of > 80% on preoperative lymphoscintigraphy. The SLN visualization rate was 90% for the last 52 cases. Two surgeons required 25 cases before consistently achieving a > or = 90% SLN identification rate in the operating room and one required 15 cases. The metastasis detection rate increased from 22% for the first 52 cases to 31% for the last 52 cases. The false negative rate for the procedure was 5%.

CONCLUSIONS

The following performance criteria and benchmarks are suggested for validating the performance of the SLN team: (1) SLN visualization rate on preoperative lymphoscintigraphy > or = 80%, (2) SLN identification rate in the operating room > or = 90%, (3) False negative rate for the procedure 5%. Thirty procedures per surgeon were sufficient to achieve these benchmarks in our group.

Для цитирования: Euhus David M, Peters George N, Leitch A Marilyn, Saboorian Hossein, Mathews Dana, Erdman William, Anglin Beth, Huth James. Validating the performance of the mammary sentinel lymph node team.. Journal of surgical oncology. 2002. DOI: 10.1002/jso.10078.

Предметные рубрики MeSH