Five-node biopsy of the axilla: an alternative to axillary dissection of levels I-II in operable breast cancer.
Аннотация
BACKGROUND
Axillary clearance of patients with early breast cancer is accompanied by a high risk of arm morbidity. Less invasive ways to establish the axillary nodal status are therefore of interest, especially in women with low risk of nodal metastases.
METHODS
Four hundred and fifteen breast cancer patients (clinical stage T(0-3) N(0-1) M(0)) were operated in the axilla with a five-node biopsy followed in the same operation by a further dissection of levels I-II of the axilla in order to evaluate the accuracy of the five-node node biopsy compared with level I-II dissection.
RESULTS
In all patients the sensitivity of the five-node biopsy was 97.3% with a negative predictive value of 98.5% and a negative likelihood ratio of 0.027. Among cases detected by screening (n=204) and those clinically detected (n=197) the sensitivity of the five-node biopsy was 95.8% and 97.9% respectively, with negative predictive values of 98.7% and 98.0% and negative likelihood ratios of 0.042 and 0.021 respectively.
CONCLUSION
Five-node biopsy of the axilla has good accuracy for correctly staging the axilla in both clinically and screening-detected cases. Five-node biopsy is an alternative to axillary clearance and sentinel node biopsy in patients with operable breast cancer.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.