MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1089/lap.2022.0344

Медицинская библиотека · Journal of laparoendoscopic & advanced surgical techniques. Part A · 2022

The Effects of Lateral 45° Head-Down Position and Carbon Dioxide Pneumoperitoneum on the Optic Nerve Sheath Diameter in Patients Undergoing Laparoscopic Transperitoneal Nephrectomies: A Prospective Observational Study.

Atasever Ayşe Gülşah, Salviz Emine Aysu, Şentürk Çiftçi Hayriye, Bingül Emre Sertaç, Sivrikoz Nükhet, Erdem Selcuk, Savran Karadeniz Meltem

Наблюдательное исследованиеСтатьяПеревод в очереди

Аннотация

Background

The aim of this study is to assess the extent of the increased intracranial pressure resulting from lateral decubitus and 45° downward positioning using sonographic optic nerve sheath diameter (ONSD) in patients undergoing laparoscopic transperitoneal nephrectomy. In addition, we evaluated the effect of the carbon dioxide pneumoperitoneum (CO2PP) on ONSD. Materials and

Methods

Twenty-four adults were enrolled in this prospective observational study. Longitudinal and transverse ONSDs were measured for each eye by ocular ultrasonography. The values were noted in supine position (T0), 20 minutes after induction of anesthesia (T1), after insufflation of the abdomen in lateral 45° head-down position (T2), at 30-minute intervals during surgery (T3-T4-T5), during lateral 45° head-down position after CO2 exsufflation (T6), before awakening while supine (T7), and at postoperative 24th hour (T8). Hemodynamic and respiratory parameters were investigated at the measurement time points.

Results

Average ONSD values for the lower eye was T0 = 4.27 ± 0.4 mm, T1 = 4.56 ± 0.6 mm, T2 = 4.84 ± 0.6 mm, T3 = 4.91 ± 0.4 mm, T4 = 4.99 ± 0.5 mm, T5 = 4.97 ± 0.5 mm T6 = 4.96 ± 0.5 mm, T7 = 4.76 ± 0.4 mm, T8 = 4.36 ± 0.5 mm and for the upper eye was T0 = 4.24 ± 0.4 mm, T1 = 4.39 ± 0.5 mm, T2 = 4.54 ± 0.5 mm, T3 = 4.60 ± 0.4 mm, T4 = 4.66 ± 0.4 mm, T5 = 4.72 ± 0.7 mm, T6 = 4.68 ± 0.4 mm, T7 = 4.52 ± 0.4 mm, T8 = 4.30 ± 0.4 mm (P < .001).

Conclusion

In our study, we observed a significant increase in ONSD within minutes after the patient was placed in a head-down position. We also observed that the difference increased more with CO2PP and was proportional to the length of the surgery. We found that it regressed to initial levels at the postoperative 24th hour. Clinicaltrials.gov: NCT05185908.

Для цитирования: Atasever Ayşe Gülşah, Salviz Emine Aysu, Şentürk Çiftçi Hayriye, Bingül Emre Sertaç, Sivrikoz Nükhet, Erdem Selcuk, Savran Karadeniz Meltem. The Effects of Lateral 45° Head-Down Position and Carbon Dioxide Pneumoperitoneum on the Optic Nerve Sheath Diameter in Patients Undergoing Laparoscopic Transperitoneal Nephrectomies: A Prospective Observational Study.. Journal of laparoendoscopic & advanced surgical techniques. Part A. 2022. DOI: 10.1089/lap.2022.0344.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.