Dosing study of esmolol for reducing hemodynamic changes during lightwand intubation.

Kang Jin Ku, Yoo Sie Hyeon, Chung Jin Hun, Kim Nan Seol, Jung Ho Soon, Seo Yong Han, Chun Hea Rim, Gong Hyung Yoon, Son Hee Dong, Kim A Joo

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Lightwand is a convenient tool that can be used instead of a laryngoscope for intubation. Tracheal intubation causes direct stimulation of the larynx, drastically increasing hemodynamic values including blood pressure and heart rate. This study aims to identify the effect of different doses of esmolol on hemodynamic changes during lightwand intubation.

METHODS

The study subjects included 140 patients who underwent general anesthesia for elective surgery. The patients were randomly divided into four groups (35 patients in each group). The 'C' group only received 20 ml of normal saline, while the 'E0.5', 'E1', and 'E2' groups received 20 ml of normal saline containing esmolol-0.5 mg/kg, 1 mg/kg, and 2 mg/kg, respectively, injected 2 min prior to intubation. The patients' blood pressure, heart rate, and rate-pressure product were measured six times, before and after the intubation.

RESULTS

The degree of heart rate elevation was suppressed in the E1 and E2 groups compared to the C group, and RPP after intubation significantly decreased in the E2 group compared to the C group.

CONCLUSIONS

Esmolol injection, 1-2 mg/kg, prior to lightwand intubation effectively blunts heart rate elevation, and 2 mg/kg of esmolol injection blunts rate-pressure product elevation.

Для цитирования: Kang Jin Ku, Yoo Sie Hyeon, Chung Jin Hun, Kim Nan Seol, Jung Ho Soon, Seo Yong Han, Chun Hea Rim, Gong Hyung Yoon, Son Hee Dong, Kim A Joo. Dosing study of esmolol for reducing hemodynamic changes during lightwand intubation.. Anesthesia and pain medicine. 2020. DOI: 10.17085/apm.19067.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.